Defining Parameters
5-25
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
5.4
Parameterization with “Parameterize FM 353”
Entering the values
You have a variety of options for entering your parameterization data.
1. User data
You can input values or select texts in a table. Select input fields with the cursor
and enter the values. You can select the associated texts for the values with the
space key.
2. Machine data
The values are entered in dialog boxes and windows selected by option tabs.
To display the machine data in a table, select the menu
View > Table form
.
Here you can enter the values as described in the user data section.
3. Tool compensation data and increment sizes
You can input the values in a table. Select input fields with the cursor and enter
the values.
4. Traversing programs
Traversing programs are input in text format.
A comment column is included in the tables for MD, SM, and TO values. This com-
ment is not stored in the data block. It can be printed out or stored with the data in
the file on export.