Troubleshooting
11-21
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
General data errors, machine data errors, traversing program errors, continued
Cl.
Mes-
sage/
Display
Error message,
error analysis and remedy
No.
General data errors
Error response: “Warning” see Table 11-2
4 (04) 4 (04)
Frequency level 1 incorrect
CBS
Cause
Specified frequency does fall not within range of 200 kHz or
less
or
DB
Effect
Frequency level does not become effective
Elimination Input an allowed frequency value
4 (04) 5 (05)
Frequency level 2 incorrect
CBS
Cause
Specified frequency does fall not within range of 200 kHz or
less
or
DB
Effect
Frequency level does not become effective
Elimination Input an allowed frequency value
4 (04) 6 (06)
Preset incremental value too high
CBS
Cause
Incremental value is greater than 10
9
MSR
or
DB
Effect
Original incremental value is retained
DB
Elimination Input an allowable incremental value
4 (04) 7 (07)
MDI block, incorrect syntax
CBS
Cause
Incorrect M or G commands or incorrect block structure
or
DB
Effect
Original MDI block is retained
DB
Elimination Input a correct MDI block
4 (04) 8 (08)
MDI block, incorrect velocity
CBS
Cause
Velocity not within the range between > 0 and max. allow-
able traverse velocity (500 000 000 MSR/min)
or
DB
Effect
Original MDI block is retained
Elimination Input a correct MDI block
4 (04) 9 (09)
MDI block, position or dwell time incorrect
CBS
Cause
Position or dwell time falls outside the allowable values
Position:
10
9
MSR
Dwell time: > 100,000 ms
or
DB
Effect
Original MDI block is retained
Elimination Input a correct MDI block
4 (04) 10 (0A)
Zero offset value, offset value incorrect
CBS
Cause
Value falls outside the range
10
9
MSR
or
DB
Effect
Does not become effective
DB
Elimination Input a correct value
Cl. = Detail event class, No. = Detail event number, CBS = checkback signals, DB = data block
Note:
Value (xx) = Hexadecimal notation of the error number
Summary of Contents for SIMATIC FM 353
Page 22: ...Product Overview 1 12 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 32: ...Installing and Removing 3 6 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 282: ...Description of Functions 9 82 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 354: ...User Data Block AW DB B 16 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...