Troubleshooting
11-28
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
General data errors, machine data errors, traversing program errors, continued
Cl.
Mes-
sage/
Display
Error message,
error analysis and remedy
No.
Machine data errors
Error response: “Warning” see Table 11-2
5 (05) 69(45)
70 (46)
71 (47)
72 (48)
73 (49)
74 (4A)
75 (4B)
Start/Stop frequency
Frequency value for acceleration switchover
Maximum frequency
Acceleration 1
Acceleration 2
Delay 1
Delay 2
CBS
or
DB
Cause
S
Impermissible value range, see “Working range, fre-
quency generator” or
S
dependency violation on no. 70...75
Effect
DB does not become effective and is stored non-retentively
Elimination Correct and retransmit
5 (05) 76(4C)
77(4D)
78(4E)
79(4F)
80(50)
81(51)
Minimum stoppage time between two positioning operations
minimum traversing time at constant frequency
Boost duration absolute
Boost duration relative
Phase current traversing
Phase current zero speed
CBS
or
DB
Cause
Unacceptable value range
Effect
DB does not become effective and is stored non-retentively
Elimination Correct and retransmit
5 (05) 96 (60)
Software limit unacceptable
CBS
Cause
With linear axes:
Software begin limit switch greater than software limit switch
end
with rotary axes:
Software begin/end limit switches not within rotary axis cycle
and not at maximum input value.
or
DB
Effect
DB does not become effective and is stored non-retentively
Elimination Correct and retransmit
5 (05) 99 (63)
Impermissible actual value evaluation factor
CBS
Cause
Impermissible relationship in the assignments for distance
per motor revolution (MD11, 12) and increments per motor
revolution (MD13) (see Section 5.3.1).
or
DB
Effect
DB does not become effective and is stored non-retentively.
Elimination Correct and retransmit.
Cl. = Detail event class, No. = Detail event number, CBS = checkback signals, DB = data block
Note:
Value (xx) = Hexadecimal notation of the error number
Summary of Contents for SIMATIC FM 353
Page 22: ...Product Overview 1 12 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 32: ...Installing and Removing 3 6 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 282: ...Description of Functions 9 82 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 354: ...User Data Block AW DB B 16 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...