Programming the Technological Functions
6-15
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
S
Job request status
You can read the status of the job request in return value RET_VAL and in the
“Write/read job in progress” signals in user data block AW-DB (DBX68.0 and
DBX68.2). You can evaluate the status of an individual job request by evaluat-
ing the Initiate, Ready and Error signals for that job request.
Table 6-2
Job request status
Job Request Status
RET_VAL
(integer)
Jobs in
Progress
(DBX68.0
DBX68.2)
Initiate
Signals
(DBB34...43)
Ready
Signals
(DBB44...53)
Error
Signals
(DBB54...63)
1. Job in progress
1
1
1
−
−
2. Job terminated without
error
0
−
−
1
−
3. Write job terminated with
error in this job
−
1
−
−
1
1
4. Write job aborted or not
executed
−
1
−
−
−
1
5. Read job aborted
−
2
−
−
−
1
6. Write and Read aborted
or not executed (in the
case of simultaneous job
requests)
−
3
−
−
−
1
−
Irrelevant for error evaluation
Processing status
Signal
Description
Write not possible
(AW-DB, DBX68.1)
= TRUE; Write request cannot be serviced in this cycle because:
S
The axis is not initialized
S
Test mode is enabled
S
No operating mode is active
S
The selected operating mode has not yet been set
In these cases, you can leave the Write request pending or you can cancel it.
The POS_CTRL block resets the signal when all of the above-listed condi-
tions are fulfilled.
Read not possible
(AW-DB, DBX68.3)
= TRUE; Read request cannot be serviced at this time because:
S
The axis is not initialized
S
No mode has been selected
S
Test mode is enabled
In these cases, you can leave the Read request pending or you can cancel
it. The POS_CTRL block resets the signal when all of the above-listed condi-
tions are fulfilled.
Reset status/error
(AW-DB, DBX69.1)
With this signal you can reset
all
Ready and Error signals prior to processing
of the pending job requests. The signal itself is then reset by the block.
Summary of Contents for SIMATIC FM 353
Page 22: ...Product Overview 1 12 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...