Troubleshooting
11-29
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
General data errors, machine data errors, traversing program errors, continued
Cl.
Mes-
sage/
Display
Error message,
error analysis and remedy
No.
Machine data errors
Error response: “Warning” see Table 11-2
5 (05) 102 (66)
Limitation, software limit for linear axis
CBS
Cause
For step resolutions < 1 MSR, the permissible traversing
range in the ratio of MSR to increments is limited (e.g. for 0.5
µ
m per step to 0.5
10
9
MSR) (see Section 5.3.1).
or
DB
Effect
DB does not become effective and is stored non-retentively.
Elimination Correct and retransmit.
Traversing program errors
Error response: “Warning” see Table 11-2
8 (08) 1 (01)
Program selection, subprogram number incorrect
CBS
Cause
S
The subroutine requested in the program is not in place
on the FM 353.
S
The subprogram called in the program contains another
subprogram call. Nesting is not possible.
or
DB
Effect
Program selection is not executed
Elimination
S
Parameterize and read in program, correct as necessary
S
Select another program
8 (08) 8 (08)
Program selection, program number not in place
CBS
Cause
The program was not parameterized, not in place on the
FM 353.
or
DB
Effect
Program selection is not executed
Elimination
S
Parameterize and read in program, correct as necessary
S
Select another program
8 (08) 9 (09)
Program selection, block number not in place
CBS
Cause
The block number is missing in the program selected
or
DB
Effect
Program selection is not executed
DB
Elimination
S
Correct program
S
Select different block number
8 (08) 10 (0A)
Program, block number unacceptable
CBS
Cause
Block number missing or outside of the number range
or
DB
Effect
Program is not stored
DB
Elimination Correct program
Cl. = Detail event class, No. = Detail event number, CBS = checkback signals, DB = data block
Note:
Value (xx) = Hexadecimal notation of the error number
Summary of Contents for SIMATIC FM 353
Page 22: ...Product Overview 1 12 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 32: ...Installing and Removing 3 6 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 282: ...Description of Functions 9 82 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 354: ...User Data Block AW DB B 16 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...