Defining Parameters
5-20
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
5.3.2
Increments
DB structure
Table 5-5 gives you a general view of the structure of the “Increments” data block
(DB-SM).
Table 5-5
DB structure
−
increments
Byte
Variable type
Value
Significance of the variables
Comment
DB header
0
WORD
Rack slot
Module address
2
WORD
DB No. (
1000)
As in DB header
4
DWORD
Reserved
8
WORD
Error No. (from FM)
With HMI services
10
WORD
1
Channel number
12
2 STRING
SM
DB identifier/type
2 ASCII characters
16
DWORD
353
Module identifier
FM 353
20
4 CHAR
0
Version number/block number
(DB structure)
24
DWORD
1
−
3
Measurement-system grid per MD7
Unit of measurement
28
WORD
0/1
Parameter (DB) backup
Job via HMI
30
WORD
Reserved
32
DWORD
0
−
10
9
Increment 1
36
DWORD
0
−
10
9
Increment 2 to increment 100
Input of values
Values are input in the increments menu of the “Parameterize FM 353” parameter-
ization tool.
Fig. 5-6
Entering values for incremental dimensions