Starting up
7-12
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Checklist
When starting up the machine axis, it is important to perform the following steps in
the indicated sequence. Steps 1 to 5 are always necessary; the rest are optional,
depending on your own application.
Table 7-4
Checklist - startup of machine axis
Step
Check
What to do?
Page
OK
1
Activation of machine data
2
Evaluation of operating characteristic curves of
the stepper motor
3
Basic startup of stepper motor control
4
Optimization of dynamic response
5
Readjustment of reference point coordinates
6
Activation of stepper motor diagnostics
7
Activation of software limit switches and back-
lash compensation
Note
In order for an axis to start, the start enable checkback signal must have been set.
If there is no start enable, this may be because:
S
“Drive enable” is not set
S
“Stop” is set
S
“Operation in progress” is active