Human-machine Interface
8-24
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Control and checkback signals, continued
German
Description
English
BA
MODE_IN
Mode
Code
Jog
01
Control
02
Reference point approach
03
Incremental relative
04
MDI
06
Automatic
08
Automatic single block
09
BP
MODE_TYPE
Operating parameters
Code
Speed levels
1 and 2
Frequency levels
1 and 2
Incremental dimension selection
1...100, 254
OVERR
OVERRIDE
Override
Checkback signals
TFGS
TST_STAT
Switching of P bus interface completed
BF/FS
OT_ERR
Operator/traversing errors
DF
DATA_ERR
Data error
PARA
PARA
Channel initialized
SFG
ST_ENBLD
Start Enable
BL
WORKING
Execution in progress
WFG
WAIT_EI
Waiting for external Enable
T-L
DT_RUN
Dwell time running
PBR
PR_BACK
Reverse program scanning
BAR
MODE_OUT
Active mode
SYN
SYNC
Channel synchronized
ME
MSR_DONE
Measurement completed
FR
−
GO_M
Negative travel
FR+
GO_P
Positive travel
SRFG
ST_SERVO
Servo enable status
FIWS
FVAL_DONE
On-the-fly setting of actual value completed
PEH
POS_RCD
Position reached. Stop.
MNR
NUM_MF
M function number
AMF
STR_MF
M function modification
J
Summary of Contents for SIMATIC FM 353
Page 22: ...Product Overview 1 12 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 32: ...Installing and Removing 3 6 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 282: ...Description of Functions 9 82 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 354: ...User Data Block AW DB B 16 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...