Troubleshooting
11-27
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
General data errors, machine data errors, traversing program errors, continued
Cl.
Mes-
sage/
Display
Error message,
error analysis and remedy
No.
Machine data errors
Error response: “Warning” see Table 11-2
5 (05) 32 (20)
Type of output, M-function
CBS
Cause
Type of output, M-function not defined
or
DB
Effect
DB does not become effective and is stored non-retentively
DB
Elimination Correct and retransmit
5 (05) 33 (21)
Output time, M-function
CBS
Cause
Unacceptable value range
or
DB
Effect
DB does not become effective and is stored non-retentively
DB
Elimination Correct and retransmit
5 (05) 34 (22)
Digital inputs
CBS
Cause
Inputs undefined or defined more than once
or
DB
Effect
DB does not become effective and is stored non-retentively
DB
Elimination Correct and retransmit
5 (05) 35 (23)
Digital outputs
CBS
Cause
Outputs undefined or defined more than once
or
DB
Effect
DB does not become effective and is stored non-retentively
DB
Elimination Correct and retransmit
5 (05) 36 (24)
Input adapter
CBS
Cause
Input adapter undefined
or
DB
Effect
DB does not become effective and is stored non-retentively
DB
Elimination Correct and retransmit
5 (05) 52 (34)
53 (35)
Velocity for backlash compensation
Backlash compensation mode
CBS
or
Cause
Impermissible value range or dependency violation
or
DB
Effect
DB does not become effective and is stored non-retentively.
Elimination Correct and retransmit.
5 (05) 67(43)
68 (44)
Special control signals
Number of increments per current-sourcing cycle
CBS
or
Cause
Impermissible value range or dependency violation on no.
or
DB
Effect
DB does not become effective and is stored non-retentively
Elimination Correct and retransmit
Cl. = Detail event class, No. = Detail event number, CBS = checkback signals, DB = data block
Note:
Value (xx) = Hexadecimal notation of the error number
Summary of Contents for SIMATIC FM 353
Page 22: ...Product Overview 1 12 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 32: ...Installing and Removing 3 6 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 282: ...Description of Functions 9 82 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 354: ...User Data Block AW DB B 16 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...