Human-machine Interface
8-8
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Description of the screens in the user interface, continued
Screen name
Description
Screen
No.
Machine data
PIC722
This screen contains input/output fields. Input of values is password
protected. The values entered are in the user DB. You can use the
soft keys to set bits in the user DB:
S
Soft key “lesen”
−
You can use this soft key to insert a memory bit
(in the user DB) which causes the user program to read the item of
machine data whose number has been entered.
S
Soft key “set”
−
You can use this soft key to set a bit which causes
the user program transfer to the FM 353 the number entered un-
der value for the item of machine data under MD No.
S
Soft key “aktiv”
−
You can use this soft key (activate MD) to set a
memory bit (“activate MD” bit in the user DB) which is transmitted
from the user program to the FM 353.
Each bit in the user DB which you set in this screen must be reset by
the user program following execution of the function.
Settings for startup
PIC723
The fields of this screen which are identified by an “x” are display
fields. If the bit is set, you will see an x. If the bit is not set, the field will
be blank. The other fields are text entry fields in which you can toggle
between “x” and “ ”.
You can use the soft keys “<<” and “>>” to change between the inset
screens of this screen.
Set data for the
“Control” operating
mode
PIC7122 This illustration contains input/output fields for the frequency levels or
a text field for frequency level selection (Selection 1 or 2 possible).
Set data for the “in-
cremental mode, rel-
ative” operating
mode
PIC7123 This screen contains input/output fields. The fields “SM-No.” and “free
SM” are addressed to the same address in the user DB. You can use
the SM No. to enter the values 1 to 100. The “free SM” field is a text
field and you can toggle back and forth between “x” and “”. If you se-
lect “x”, this corresponds to the value 254 for free SM. The value of
the free SM is found in the user DB.
Set data for the “MDI”
operating mode
PIC7124 This screen contains input/output fields. The MDI data record must be
preassigned by the user program with the corresponding bits (G, X, F
bits are set) and possibly, with values for G, X and F. The entry field
behind G is a text field. There, you can select between the values 90
and 91.
Using the soft key “set” you can set a memory bit (in the user DB),
which must be analyzed by the user program. With modification of this
bit, the MDI block must be transmitted from the user DB to the
FM 353, and the bit must be reset.
Summary of Contents for SIMATIC FM 353
Page 22: ...Product Overview 1 12 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 32: ...Installing and Removing 3 6 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 282: ...Description of Functions 9 82 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 354: ...User Data Block AW DB B 16 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...