![Siemens SIMATIC FM 353 Manual Download Page 76](http://html.mh-extra.com/html/siemens/simatic-fm-353/simatic-fm-353_manual_1265357076.webp)
Defining Parameters
5-24
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Input of traversing programs
An empty window is provided for the input of NC traversing programs. Here you
can input your traversing program as follows:
Fig. 5-8
Entry for traversing programs
1. % Program number Program name
The “%” can be input only in the first line. This input is mandatory. The DB num-
ber is formed from the program number.
The program name is optional and may have up to 18 characters.
2. N
<
block number
>
−
G
<
command
>
(G1, G2, G3)
−
X
<
value
>
−
F
<
value
>
−
M
<
command
>
(M1, M2, M3)
−
D
<
No.
>
(tool offset number)
−
L
<
No.
>
−
P
<
No.
> −
(for NC programming see Chapter 10).
−
You must enter the block number (N)
first and in ascending order
. The
rest of the inputs may be in any desired sequence.
−
Input separators as a blank.
You must enter characters in upper case letters.
You can also use the input area at the top of the screen. The program number and
the program name are saved when you exit the input box. You can save the tra-
versing blocks with the “Save Block” button.
Summary of Contents for SIMATIC FM 353
Page 22: ...Product Overview 1 12 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 32: ...Installing and Removing 3 6 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 282: ...Description of Functions 9 82 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 354: ...User Data Block AW DB B 16 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...