Human-machine Interface
8-22
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Parameters/data of the DB-SS (DB No. 1000), continued
Offset
1)
Comment
Significance of the variables
Value
Variable type
284
DINT
Switch readjustment in “Reference point
approach” mode
Servicing data
288
DINT
Free
Servicing data
292
8 x DINT
Free
324
BYTE
Override
Add. operating data
325
BYTE
NC part program no.
326
BYTE
NC block no.
Add. operating data
327
BYTE
No. of callup subroutine loops
Add. operating data
328
BYTE
G90/91 Active
Add. operating data
329
BYTE
G60/64 Active
Add. operating data
330
BYTE
G43/44 Active
Add. operating data
331
BYTE
Active D No.
Add. operating data
332
332.1
8 x BOOL
BOOL
Status messages 1
S
Velocity limitation to limit value from
MD
Additional operating
data
333
333.0
333.1
333.3
8 x BOOL
BOOL
BOOL
BOOL
Status messages 2
S
Start/Stop frequency
S
Frequency value f. accel. switching
S
Acceleration/delay value is limited
334
2 x BYTE
Free
336
4 x 8 x BOOL
Diagnostics, system-specific
340
4 x BYTE
Diagnostics, channel-specific
Identifier
344
2 x 8 x BOOL
Diagnostics, channel-specific
Channel error
346
4 x 8 x BOOL
Free
350
2 x BYTE
Error number DS 162
Operator/travel error
352
BYTE
Free
353
BYTE
Free
354
2 x BYTE
Error number DS 163
Data error
356
BYTE
Free
357
BYTE
Free
358
2 x BYTE
Error number DS 164
Operational error
360
BYTE
Free
361
BYTE
Free
362
32 x BOOL
Process interrupt
1) A variable in the S7 protocol is addressed by the DB No. and, depending on data format, by the DBB, DBW
and DBD No. (offset in DB), as well.
Summary of Contents for SIMATIC FM 353
Page 22: ...Product Overview 1 12 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 32: ...Installing and Removing 3 6 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 282: ...Description of Functions 9 82 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 354: ...User Data Block AW DB B 16 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...