Writing Traversing Programs
10-18
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Sample programming (standard case)
The following figure shows a sample program with the programming flow.
/
N G1
G2
G3
X/t
F
M1
M2
M3
D
100 00
10 000
10
90
64
5
15
20
25
64
20 000
30 000
40 000
30 000
200 00
150 00
100 00
t
V
N5
N10
N15
N20
N25
1
2
3
4
5
1
−
Block N10 is started at the point of deceleration of N5.
2
−
N15 is started at the point of deceleration of N10. Acceleration to the higher traversing
speed begins when the set position of N10 is reached.
3
−
N20 is started at a lower traversing speed at the braking point of N15.
4
−
When the traversing direction is changed, the axis decelerates to a standstill.
5
−
When the target range is reached, the axis accelerates in the opposite direction up to
the traversing speed of the new block.
To be able to approach a position correctly, the axis must calculate the point of de-
celeration. The relevant parameters for this calculation are the residual traversing
distance, the deceleration value and the current traversing speed.
The point of deceleration is also the earliest possible time for a block change.
Summary of Contents for SIMATIC FM 353
Page 22: ...Product Overview 1 12 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 32: ...Installing and Removing 3 6 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 282: ...Description of Functions 9 82 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 354: ...User Data Block AW DB B 16 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...