Programming the Technological Functions
6-38
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Control/checkback signals
German
Description
AW-DB
English
R+
DIR_P
DBX15.3 Positive direction
QMF
ACK_MF
DBX15.4 Acknowledge M function
EFG
READ_EN
DBX15.5 Read Enable
SA
SKIP_BLK
DBX15.6 Skip block
AF
DRV_EN
DBX15.7 Drive enable
BA
MODE_IN
DBB16
Operating mode
Code
Jog
01
Control
02
Approach to reference point
03
Incremental mode, relative
04
MDI
06
Automatic
08
Automatic single block
09
BP
MODE_TYPE
DBB17
Operating mode parameters
Code
Speed levels
1 and 2
Frequency levels
1 and 2
Incremental dimension selection 1...100, 254
OVERR
OVERRIDE
DBB18
Override
Checkback signals
TFGS
TST_STAT
DBX22.1 Switching of P BUS interface completed
BF/FS
OT_ERR
DBX22.3 Operator-/traversing error
DF
DATA_ERR
DBX22.4 Data error
PARA
PARA
DBX22.7 Channel initialized
SFG
ST_ENBLD
DBX23.0 Start Enable
BL
WORKING
DBX23.1 Process in progress
WFG
WAIT_EI
DBX23.2 Wait for external Enable
T-L
DT_RUN
DBX23.5 Dwell time running
PBR
PR_BACK
DBX23.6 Reverse program scanning
BAR
MODE_OUT
DBB24
Active operating mode
SYN
SYNC
DBX25.0 Channel synchronized
ME
MSR_DONE
DBX25.1 End of measurement
FR
−
GO_M
DBX25.2 Travel in negative direction
FR+
GO_P
DBX25.3 Travel in positive direction
SRFG
ST_SERVO
DBX25.4 Servo enable status
FIWS
FVAL_DONE
DBX25.5 Setting of on-the-fly actual value successfully
completed
PEH
POS_RCD
DBX25.7 Position reached. Stop.
MNR
NUM_MF
DBB26
M function number
AMF
STR_MF
DBX27.4 M function modification
ACT_POS
ACT_POS
DBD28
Actual positon
Summary of Contents for SIMATIC FM 353
Page 22: ...Product Overview 1 12 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 32: ...Installing and Removing 3 6 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 282: ...Description of Functions 9 82 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 354: ...User Data Block AW DB B 16 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...