Defining Parameters
5-27
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Creating the SDB
Prerequisite: Online connection with the FM 353
Select menu
File > Create SDB
If no DB-MD exists on the FM 353
→
Abort
No
No associated SDB exists
SDB is created and stored in the S7 project in
CPU\S7-Program\Blocks\System data
An associated SDB
1 000
exists for the FM 353 in the
S7 project.
Yes
Abort
Overwrite this SDB?
Yes
No
Fig. 5-9
Creating SDB
1 000
Display/delete SDB in the S7 project
Select menu
File > Display SDB
All SDBs for FM 353 of the project are
displayed
Delete SDB?
No
Yes
Select SDB and delete
Close the window
Fig. 5-10
Displaying/deleting SDB