12.25
AT+FTH Transmit Data Using HDLC Framing
The
AT+FTH
command causes the TA to transmit data using the HDLC protocol and the modulation schemes
defined in Section
12.1
,
FAX parameters
. An ERROR response code results if the command is issued while the
modem is on-hook. The test command can be used in off-hook mode to check the modulation schemes sup-
ported by MC55.
Syntax
Note
• Used for Fax Class 1 only
Test Command
AT+FTH=?
Response(s)
In off-hook mode only:
+FTH:
(list of
<mod>
s)
OK
In on-hook mode:
ERROR
Write Command
AT+FTH=
<mod>
Response(s)
CONNECT
Reference(s)
PIN
ASC0 ASC1
MUX1
MUX2
MUX3 Charge
Last
TIA/EIA-578
!
%
!
%
!
!
!
!
!