7.6
ATD><str> Mobile originated call from active memory using cor-
responding field
Syntax
Command Description
This command searches the active phonebook for a given string
<str>
and dials the assigned phone number.
The termination character ";" is mandatory since dialing from a phonebook is only supported for voice calls and
for sending *# codes of Supplementary Services or other functions.
Parameter Description
String type value ("x"), which should equal an alphanumeric field in at least one phonebook entry in the searched
memories; used character set should be the one selected with
AT+CSCS
.
<str>
can contain escape sequences
as described in chapter "
Supported character sets
".
<str>
must be wrapped in quotation marks (""), if escape sequences or parameter
<mgsm>
are used or if the
alphanumeric strings contains a blank. If not, quotation marks are optional.
If
AT+CSCS
is set to "UCS2", with respect to the coding of UCS2-characters only phonebook entries that contain
an alphanumeric string with as size less than the half of the parameter
<tlength>
from
AT+CPBW
can be
dialed.
String of GSM modifiers:
I Activates CLIR (disables presentation of own phone number to called party)
i Deactivates CLIR (enables presentation of own phone number to called party)
Notes
• This command may be aborted generally by receiving a character during execution. Abortion is not possible
during some states of connection setup such as handshaking.
• The command is not applicable to data calls. Any attempt to dial
<str>
without semicolon ";" causes the
result code "NO CARRIER" to appear.
• Parameter
<mgsm>
only if no *# code is within the dialing string.
Exec Command
ATD>
<str>
[
<mgsm>
];
Response(s)
ERROR
+CME ERROR: <err>
If no dialtone (parameter ATX2 or ATX4):
NO DIALTONE
If busy (parameter setting ATX3 or ATX4):
BUSY
If connection cannot be set up:
NO CARRIER
When TA returns to command mode after call release:
OK
If successfully connected:
OK
Reference(s)
PIN
ASC0 ASC1
MUX1
MUX2
MUX3 Charge
Last
V.250
%
%
§
%
§
§
!
!
!
<str>
(str)(+CSCS)
<mgsm>
(str)