Sleep mode
If you activate this option, the safety laser scanner changes to the sleep mode as soon
as the input conditions for this monitoring case exist.
7.13.4
Input condition
The controller transmits to the safety laser scanner in the process image the number of
the monitoring event to be activated.
For each monitoring case, the Safety Designer shows the number with which the
monitoring case is activated.
7.13.5
Cut-off paths
You can create cut-off paths and define the outputs switched by the cut-off paths.
You need a cut-off path for every field in a field set. If the field sets have different sizes,
use the field set with the most fields as a guide.
Creating cut-off path and entering a name
1.
Create a cut-off path for every field in the largest field set.
2.
Enter a descriptive name for each cut-off path.
Assigning the number of the cut-off path in the process image
b
Select the desired number.
✓
The number is assigned to the cut-off path.
Restart behavior
You define the restart behavior for all network outputs in the
Inputs and outputs
window.
If needed, define a deviating restart behavior for one or several network outputs.
7.13.6
Assigning field sets
Assigning a field set to a monitoring case
The field sets that have been created are listed in the
Field sets
area.
1.
Create cut-off paths,
2.
Drag the field set onto the monitoring case.
✓
The fields in a field set are arranged as they were drawn in the field editor (for
example protective field, warning field, warning field).
Deleting the assignment of a field set from the monitoring case
b
Drag the field set from the monitoring case table onto the trash-can icon.
✓
The field set is removed from the relevant monitoring case.
Defined cut-off behavior
DANGER
Hazard due to lack of effectiveness of the protective device
Persons and parts of the body to be protected may not be recognized in case of
non-observance.
The
Always ON (safe)
function has the same effect as a field which is always clear. In
a monitoring case with the
Always ON (safe)
function, the cut-off path containing this
function is permanently in the ON state.
b
Drag the
Always OFF
function onto the cut-off path.
CONFIGURATION