Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
4
CurrentMonitoringCaseNoTable1
5
Reserved
DeviceError
Applicatio‐
nError
1)
Cut-off paths 5 to 8 are only available for the Pro performance package.
13.6.2
Alarms
Table 47: Available alarms (degree of difficulty: need for maintenance)
Number
Severity
Description
Troubleshooting
64
Error
Incorrect F destination address
(F_Dest_Add) set
b
Check the PROFIsafe parameters of the
module.
65
Error
Invalid F destination address (F_Dest_Add)
set
b
Check the PROFIsafe parameters of the
module.
66
Error
Invalid or incorrect F source address
(F_Source_Add) set
b
Check the PROFIsafe parameters of the
module.
67
Error
The fail-safe monitoring time (F_WD_Time)
is set to an invalid value of 0 ms
b
Check the PROFIsafe parameters of the
module.
68
Error
The set parameter F_SIL exceeds the
safety integrity level (SIL) of the device
b
Check the PROFIsafe parameters of the
module.
69
Error
The set parameter F_CRC_Length does not
match the length of the received CRC val‐
ues
b
Check the PROFIsafe parameters of the
module.
70
Error
F parameter version set incorrectly
b
Check the PROFIsafe parameters of the
module.
71
Error
Inconsistent F parameter block received
(CRC1 error)
b
Rebuild and load the safety program.
72
Error
Device-specific or unspecified diagnostic
message
75
Error
iParameter inconsistent (F_iPar_CRC error)
b
Check the set F_iPar_CRC.
b
Process image without checking the
F_iPar_CRC.
76
Error
F_Block_ID not supported
b
Check the PROFIsafe parameters of the
module.
77
Error
PROFIsafe transmission error: data incon‐
sistent (CRC2 error)
b
Check wiring for damage and possible
electromagnetic interference (EMC).
78
Error
PROFIsafe transmission error: Monitor‐
ing time (F_WD_Time or F_WD_Time_2
expired)
b
Increase, if necessary, the watchdog
time set in the PROFIsafe parameters.
256
Need for mainte‐
nance
Error in application of the safety laser
scanner
b
Check the configuration, control and
process of the machine.
257
Need for mainte‐
nance
Internal error in the safety laser scanner
b
Restart device.
b
Replacing the safety laser scanner.
258
Need for mainte‐
nance
Contamination warning
b
Check the optics cover for damage.
b
Clean the optics cover.
259
Need for mainte‐
nance
Contamination error
All safety outputs in the OFF state.
b
Check the optics cover for damage.
b
Clean the optics cover.
260
Need for mainte‐
nance
Tamper protection (reference contamina‐
tion field)
The safety laser scanner does not detect
any contour within the configured toler‐
ance band of the reference contour field.
All safety outputs in the OFF state.
13
TECHNICAL DATA
152
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 – PROFINET
8027931/2022-10-24 | SICK
Subject to change without notice