Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
10
Reserved
11
Reserved
TriggerDevi‐
ceReboot‐
WithNetwork
TriggerDevi‐
ceRebootWi‐
thoutNet‐
work
1)
Cut-off paths 5 to 8 are only available for the Pro performance package.
Table 42: Safety-related PROFIsafe process image: output of the device, input of the control
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Reserved
Manipula‐
tionStatus
Reference‐
ContourSta‐
tus
Contamina‐
tionError
Contamina‐
tionWarning
Standbymo‐
deActive
RunModeac‐
tive
1
1)
SafeCutOff‐
Path08
SafeCutOff‐
Path07
SafeCutOff‐
Path06
SafeCutOff‐
Path05
SafeCutOff‐
Path04
SafeCutOff‐
Path03
SafeCutOff‐
Path02
SafeCutOff‐
Path01
2
Reserved
3
1)
NonsafeCu‐
tOffPath08
NonsafeCu‐
tOffPath07
NonsafeCu‐
tOffPath06
NonsafeCu‐
tOffPath05
NonsafeCu‐
tOffPath04
NonsafeCu‐
tOffPath03
NonsafeCu‐
tOffPath02
NonsafeCu‐
tOffPath01
4
Reserved
5
1)
ResetRequir‐
edCutOff‐
Path08
ResetRequir‐
edCutOff‐
Path07
ResetRequir‐
edCutOff‐
Path06
ResetRequir‐
edCutOff‐
Path05
ResetRequir‐
edCutOff‐
Path04
ResetRequir‐
edCutOff‐
Path03
ResetRequir‐
edCutOff‐
Path02
ResetRequir‐
edCutOff‐
Path01
6
Reserved
7
CurrentMonitoringCaseNoTable1
8
CurrentMonitoringCaseNoTable2
9
CurrentMonitoringCaseNoTable3
10
CurrentMonitoringCaseNoTable4
11
Reserved
DeviceError
Applicatio‐
nError
1)
Cut-off paths 5 to 8 are only available for the Pro performance package.
Table 43: Non-safety-related PROFINET process image: output of the device, input of the control
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Reserved
Manipula‐
tionStatus
Reference‐
ContourSta‐
tus
Contamina‐
tionError
Contamina‐
tionWarning
Standbymo‐
deActive
RunModeac‐
tive
1
1)
StatusSafe‐
CutOff‐
Path08
StatusSafe‐
CutOff‐
Path07
StatusSafe‐
CutOff‐
Path06
StatusSafe‐
CutOff‐
Path05
StatusSafe‐
CutOff‐
Path04
StatusSafe‐
CutOff‐
Path03
StatusSafe‐
CutOff‐
Path02
StatusSafe‐
CutOff‐
Path01
2
Reserved
3
1)
NonsafeCu‐
tOffPath08
NonsafeCu‐
tOffPath07
NonsafeCu‐
tOffPath06
NonsafeCu‐
tOffPath05
NonsafeCu‐
tOffPath04
NonsafeCu‐
tOffPath03
NonsafeCu‐
tOffPath02
NonsafeCu‐
tOffPath01
4
Reserved
5
1)
ResetRequir‐
edCutOff‐
Path08
ResetRequir‐
edCutOff‐
Path07
ResetRequir‐
edCutOff‐
Path06
ResetRequir‐
edCutOff‐
Path05
ResetRequir‐
edCutOff‐
Path04
ResetRequir‐
edCutOff‐
Path03
ResetRequir‐
edCutOff‐
Path02
ResetRequir‐
edCutOff‐
Path01
6
Reserved
7
CurrentMonitoringCaseNoTable1
8
CurrentMonitoringCaseNoTable2
9
CurrentMonitoringCaseNoTable3
10
CurrentMonitoringCaseNoTable4
13
TECHNICAL DATA
150
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 – PROFINET
8027931/2022-10-24 | SICK
Subject to change without notice