5
10
20
50
D [m]
D [m]
R [%]
500
200
100
50
20
10
5
2
1
6
5
3
2
4
1
Figure 76: Scanning range and required remission for warning fields
R
Required minimum remission in %
D
Range in m
1
Black shoe leather
2
Matt black paint
3
Gray cardboard
4
Writing paper
5
White plaster
6
Reflectors > 2,000%, reflective tapes > 300%
13.6
Data exchange in the network
13.6.1
Process images in detail
13.6.1.1
Available data
13.6.1.1.1
Input of the device (output of the control)
Table 39: Input of the device (output of the control)
Name
Use
Data type
Definition
Values
Safety implica‐
tion
ActivateStandbyMode
Additional func‐
tion
BOOL
Activate sleep mode
Activates sleep mode.
0 = no sleep
mode
Parameter with‐
out safety impli‐
cation
1 = sleep mode
13
TECHNICAL DATA
144
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 – PROFINET
8027931/2022-10-24 | SICK
Subject to change without notice