outdoorScan3 Pro – PROFINET
Single shock
50 m/s², 11 ms
Continuous shock
•
100 m/s², 16 ms
•
150 m/s², 6 ms
EMC
In accordance with IEC 61496-1, IEC 61000-6-2, and
IEC 61000-6-4
1)
The specified enclosure rating is only valid if the safety laser scanner is closed, the system plug and
the cover plate are mounted, and all of the M12 plug connectors of the safety laser scanner have been
closed using a male cable connector suitable for the enclosure rating or using a protective cap.
2)
Values outside specification can prematurely age the device. Values outside specification can affect the
safety laser scanner. This may have a negative impact on the availability of the machine. That is to say,
the safety laser scanner switches off the machine even though there are no people in the protective field.
3)
The temperature of the device must be at least –10 °C when switched on. At lower temperatures the
device must be warmed up before it is switched on.
4)
IEC 61496-1, no. 4.3.1 and no. 5.4.2, IEC 61496-3, no. 4.3.1 and no. 5.4.2. Condensation has an
influence on normal operation.
5)
For direct mounting.
Miscellaneous data
Table 36: Miscellaneous data
outdoorScan3 Pro – PROFINET
Wavelength
845 nm
Detectable remission
1.8% … several 1000%
Maximum uniform contami‐
nation of the optics cover
without reducing the detec‐
tion capability
1)
30%
Area where detection capabil‐
ity is restricted
≤ 50 mm
2)
Light spot size
3)
Devices with a max. protective field range of 4.0 m
At front screen 18 mm × 4 mm
At 4.0 m distance 5 mm × 11 mm
At 5.5 m distance 2 mm × 18 mm
At 9.0 m distance 11 mm × 27 mm
Divergence of collimated
beam
0.17°
Receiving angle
0.75°
Pulse duration
Type 4 ns
Average output power
9.2 mW
Laser class
1M
Measurement error with
measurement data output
Type ± 25 mm
1)
In the event of heavy contamination, the safety laser scanner displays a contamination error and
switches all safety outputs to the OFF state.
2)
In close proximity (50 mm-wide area in front of the optics cover), the detection capability of the safety
laser scanner may be restricted. If required, this area must be secured using an undercut or frame, for
example.
3)
W × H when the laser beam exits at a 90° angle to the front.
TECHNICAL DATA
13
8027931/2022-10-24 | SICK
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 – PROFINET
141
Subject to change without notice