Functions and settings
You can activate, deactivate or select the default setting for each function displayed.
The default setting depends on the device and its range of functions. The default
setting is displayed in the
Physical device
area.
Safety Designer displays the minimum functionality that the device must have to sup‐
port the setting.
Behavior if the "deactivated" setting is not supported by the device or replacement device:
It may happen that settings are stored in the system connector that the device cannot
evaluate, e.g. because a device has been replaced by an older device. You can set how
the device should behave in this case.
Older devices ignore all settings in this window. Safety Designer shows up to which
functional range the settings are ignored.
7.19.4.1
Functions and settings
Device restart (without network) via device display
You can specify whether the device can be restarted using the pushbuttons on the
display.
USB (Device configuration and diagnosis)
If you deactivate the USB interface and service work is to be performed on the device
at a later time, the service technicians (e.g. from SICK) may have to be given access to
your network.
As soon as the interface is deactivated, no new connections can be established. An
existing connection remains open until it is closed or the timeout expires.
At least one interface must be active so that you can access the device. Safety
Designer prevents the transfer of a configuration in which all configuration interfaces
are deactivated.
PROFINET CoLa 2
You can activate or deactivate the CoLa 2 interface for all PROFINET connections.
The CoLa 2 interface enables device configuration and diagnostics with Safety Designer
via network. For information on further functions of the CoLa 2 interface, refer to the
technical information “microScan3, outdoorScan3, nanoScan3: Data output via UDP
and TCP/IP” (part number 8022706).
As soon as the interface is deactivated, no new connections can be established. An
existing connection remains open until it is closed or the timeout expires.
7.19.5
Compare configuration
Overview
You can use this function to compare the current configuration in the device window
with a previously exported configuration or the configuration in the device.
Exported configurations are stored in their own format: “.sdsc”. You can export a
configuration under
Service
>
Compare configurations
in the
Current configuration of project
area in the device window.
Prerequisites
•
The configuration export contains only one device.
•
Type code of the device is identical in both configurations.
•
Version number of the functionality is identical in both configurations.
7
CONFIGURATION
108
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 – PROFINET
8027931/2022-10-24 | SICK