7.12
Inputs and outputs
Overview
Figure 56: Inputs and outputs
1
Input source
2
Input for switching between monitoring cases
3
Restart behavior of the network outputs
4
Input for additional functions
5
Network outputs
6
Behavior during connection termination
Safety Designer provides a selection of the possible signal inputs.
Use one input source
You specify which process image is to be used.
The selected process image is used by the safety laser scanner as the input source
for monitoring case switching, for the reset signal, and for other functions (restart the
device or activate the sleep mode).
For its output data, the safety laser scanner automatically uses the process image that
corresponds to the process map chosen as the input source (same length).
The process image chosen here must have the same length (6 bytes or 12 bytes) as the
process image configured in the controller for the safety laser scanner.
CONFIGURATION
7
8027931/2022-10-24 | SICK
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 – PROFINET
95