Name
Use
Data type
Definition
Values
Safety implica‐
tion
CurrentMonitoringCaseNoTa‐
ble2
Diagnostics
USINT
Current monitoring
case (Monitoring case
table 2)
Indicates the current
(active) monitoring case
of monitoring case
table 2.
0 = no monitor‐
ing case is active
Parameter with‐
out safety impli‐
cation
1 … 254 = num‐
ber of the current
(active) monitor‐
ing case
CurrentMonitoringCaseNoTa‐
ble3
Diagnostics
USINT
Current monitoring
case (Monitoring case
table 3)
Signals the current
(active) monitoring case
of monitoring case
table 3.
0 = no monitor‐
ing case is active
Parameter with‐
out safety impli‐
cation
1 … 254 = num‐
ber of the current
(active) monitor‐
ing case
CurrentMonitoringCaseNoTa‐
ble4
Diagnostics
USINT
Current monitoring
case (Monitoring case
table 4)
Indicates the current
(active) monitoring case
of monitoring case
table 4.
0 = no monitor‐
ing case is active
Parameter with‐
out safety impli‐
cation
1 … 254 = num‐
ber of the current
(active) monitor‐
ing case
DeviceError
Diagnostics
BOOL
Device error
Signals whether a
device error (serious
error) is present, caus‐
ing the safety func‐
tion to be paused. To
resolve this, rectify the
cause of the error and
then restart the device.
0 = no device
error
Parameter with‐
out safety impli‐
cation
1 = device error
ManipulationStatus
Diagnostics
BOOL
Manipulation
Signals if manipulation
has been detected
and the safety outputs
are therefore in the
OFF state, for example
because the device has
not detected an object
over a long period of
time.
0 = no manipula‐
tion detected
Parameter with
implication for
the safety func‐
tion
1 = manipulation
detected
NonsafeCutOffPath01
Additional func‐
tion
BOOL
Cut-off path 01 (Not
safety-related)
The signal is ON if
the currently monitored
field in the cut-off path
is free.
0 = OFF state,
detection in field
Parameter with‐
out safety impli‐
cation
1 = ON state,
field free
NonsafeCutOffPath02
…
NonsafeCutOffPath08
Additional func‐
tion
BOOL
Cut-off path 02 … 08
(Not safety-related)
The signal is ON if
the currently monitored
field in the cut-off path
is free.
1)
0 = OFF state,
detection in field
Parameter with‐
out safety impli‐
cation
1 = ON state,
field free
TECHNICAL DATA
13
8027931/2022-10-24 | SICK
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 – PROFINET
147
Subject to change without notice