Name
Use
Data type
Definition
Values
Safety implica‐
tion
SafeCutOffPath02
…
SafeCutOffPath08
BOOL
Cut-off path 02 … 08
(safety-oriented)
The signal is ON, if all
of the following criteria
are met:
1)
•
The currently moni‐
tored field in the
cut-off path is
safety-oriented
•
The currently moni‐
tored field in the
cut-off path is free
•
The restart interlock
was not triggered
0 = OFF state,
detection in pro‐
tective field
Safety-relevant
parameter
1 = ON state,
protective field
free
StandbymodeActive
Diagnostics
BOOL
Status sleep mode
Signals whether the
device is in sleep
mode.
0 = device not in
sleep mode
Parameter with‐
out safety impli‐
cation
1 = device in
sleep mode
StatusSafeCutOffPath01
Additional func‐
tion
BOOL
Status of the safety-
related cut-off path 01
(Not safety-related)
Signals the status
of the relevant safety-
related cut-off path.
0 = safety-
related cut-off
path in OFF state
Parameter with‐
out safety impli‐
cation
1 = safety-
related cut-off
path in ON state
StatusSafeCutOffPath02
…
StatusSafeCutOffPath08
Additional func‐
tion
BOOL
Status of the safety-
related cut-off path
02 … 08 (Not safety-
related)
Signals the status
of the relevant safety-
related cut-off path.
1)
0 = safety-
related cut-off
path in OFF state
Parameter with‐
out safety impli‐
cation
1 = safety-
related cut-off
path in ON state
1)
Cut-off paths 5 to 8 are only available for the Pro performance package.
13.6.1.2
Content of the process images
13.6.1.2.1
Process image, length 12 bytes
Table 41: Safety-related PROFIsafe process image: input of the device, output of the control
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Reserved
ActivateS‐
tandbyMode
StopAlarm‐
Detection
Reserved
TriggerRun‐
Mode
1
SetMonitoringCaseNoTable1
2
SetMonitoringCaseNoTable2
3
SetMonitoringCaseNoTable3
4
SetMonitoringCaseNoTable4
5
Reserved
6
Reserved
7
Reserved
8
Reserved
9
1)
TriggerReset‐
CutOff‐
Path08
TriggerReset‐
CutOff‐
Path07
TriggerReset‐
CutOff‐
Path06
TriggerReset‐
CutOff‐
Path05
TriggerReset‐
CutOff‐
Path04
TriggerReset‐
CutOff‐
Path03
TriggerReset‐
CutOff‐
Path02
TriggerReset‐
CutOff‐
Path01
TECHNICAL DATA
13
8027931/2022-10-24 | SICK
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 – PROFINET
149