Display
Device or configura‐
tion
Meaning
Devices and configu‐
rations with 2 to 4
configured safety out‐
puts
Detection in the protective field in position 3 or
there is a warning field in the active monitoring
case. The associated safety output is in the
OFF state.
Safety outputs for which no object is detected
in the field and which are in the ON state are
marked with their number.
Devices and configu‐
rations with 2 to 4
configured safety out‐
puts
Cut-off paths in which no protective field is
located are not marked. The associated safety
output is in the OFF state.
A non-safety-related output can still be in the
ON state, e.g. if a warning field is free.
Devices and configu‐
rations with more than
4 configured safety
outputs
For one or more cut-off paths, the following
applies: Detection in the protective field or
there is a warning field in the active monitoring
case. The associated safety outputs are in the
OFF state.
•
Left digit: the number of safety outputs in
the OFF state
•
Right digit: the number of configured safety
outputs
Configuration with
restart interlock
Protective field is clear, reset can take place.
Configuration with
restart interlock
Reset button pressed Safety output in the OFF
state.
Configuration with
restart interlock
Reset button pressed Safety output in the ON
state.
Configuration with
automated restart
after a time
Protective field is clear, configured time to
restart expires.
Configuration with at
least one warning field
Detection in the warning field (left col‐
umn: number of warning fields with detection,
right column: number of warning fields in the
current monitoring case).
Display flashes
All devices and config‐
urations
Error. All safety outputs in the OFF state. Addi‐
tional information:
.
Display flashes
All devices and config‐
urations
Contamination warning. Check the optics cover
for damage. Clean the optics cover.
OPERATION
9
8027931/2022-10-24 | SICK
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 – PROFINET
117