Name
Use
Data type
Definition
Values
Safety implica‐
tion
ReferenceContourStatus
Diagnostics
BOOL
Reference contour
monitoring
The safety laser scan‐
ner does not detect any
contour within the con‐
figured tolerance band
of the reference con‐
tour field. All safety out‐
puts in the OFF state.
0 = contour in
the set tolerance
band or refer‐
ence contour
monitoring not
active
Parameter with
implication for
the safety func‐
tion
1 = contour not
in set tolerance
band
ResetRequiredCutOffPath01
Diagnostics
BOOL
Reset required, Cut-off
path 01
Signals whether the
device is waiting for a
reset signal to switch
safety-related cut-off
path 01 to the ON
state.
0 = reset not
required
Parameter with
implication for
the safety func‐
tion
1 = reset
required
ResetRequiredCutOffPath02
…
ResetRequiredCutOffPath08
Diagnostics
BOOL
Reset required, Cut-off
path 02 … 08
Signals whether the
device is waiting for a
reset signal to switch
the respective safety-
related cut-off path to
the ON state.
1)
0 = reset not
required
Parameter with
implication for
the safety func‐
tion
1 = reset
required
RunModeactive
Diagnostics
BOOL
Signals the operational
status of the device.
Parameter with‐
out safety impli‐
cation
1 = safety func‐
tion is executed.
SafeCutOffPath01
BOOL
Cut-off path 01 (safety-
oriented)
The signal is ON, if all
of the following criteria
are met:
•
The currently moni‐
tored field in the
cut-off path is
safety-oriented
•
The currently moni‐
tored field in the
cut-off path is free
•
The restart interlock
was not triggered
0 = OFF state,
detection in pro‐
tective field
Safety-relevant
parameter
1 = ON state,
protective field
free
13
TECHNICAL DATA
148
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 – PROFINET
8027931/2022-10-24 | SICK
Subject to change without notice