Approach
1.
In the navigation menu of the device window, navigate to
Service
>
Compare configu‐
rations
.
✓
The Safety Designer shows the current device configuration at the top left of the
workspace.
2.
Reading in comparison data:
°
Reading a configuration from the device: Open the drop-down menu next to
the device symbol and select
Read from Device
.
°
Importing a configuration file: Select and import a previously exported config‐
uration file using
Import data
.
°
Use the current configuration in the device window: Select
Use as Comparison
Data
.
✓
The Safety Designer starts the configuration comparison and displays the results
in a table in the workspace.
3.
If necessary, export the comparison result as a .csv file using
Export result
via the
comparison table.
Complementary information
Table 16: Buttons
Button
Description
Current configuration of project
area:
Exports the current configuration in the “.sdsc” format for another
comparison
Comparison data
area:
Exports the comparison configuration in the “.sdsc” format
Via the comparison table:
Exports the comparison result
Imports the configuration file in the “.sdsc” format
Identifying the device
Reads the configuration from the device
Updates the configuration comparison
CONFIGURATION
7
8027931/2022-10-24 | SICK
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 – PROFINET
109