Name
Use
Data type
Definition
Values
Safety implica‐
tion
SetMonitoringCaseNoTable1
USINT
Monitoring case num‐
ber (Monitoring case
table 1)
Activates the monitor‐
ing case with the cor‐
responding number in
monitoring case table
1.
0 = invalid
Safety-relevant
parameter
1 … 254 = num‐
ber of the moni‐
toring case
SetMonitoringCaseNoTable2
USINT
Monitoring case num‐
ber (Monitoring case
table 2)
Activates the monitor‐
ing case with the cor‐
responding number in
monitoring case table
2.
0 = invalid
Safety-relevant
parameter
1 … 254 = num‐
ber of the moni‐
toring case
SetMonitoringCaseNoTable3
USINT
Monitoring case num‐
ber (Monitoring case
table 3)
Activates the monitor‐
ing case with the cor‐
responding number in
monitoring case table
3.
0 = invalid
Safety-relevant
parameter
1 … 254 = num‐
ber of the moni‐
toring case
SetMonitoringCaseNoTable4
USINT
Monitoring case num‐
ber (Monitoring case
table 4)
Activates the monitor‐
ing case with the cor‐
responding number in
monitoring case table
4.
0 = invalid
Safety-relevant
parameter
1 … 254 = num‐
ber of the moni‐
toring case
StopAlarmDetection
Additional func‐
tion
BOOL
Stop Event history
0 = event history
active, object
detections are
recorded
Parameter with‐
out safety impli‐
cation
1 = event history
not active, object
detections are
not recorded,
existing record‐
ings are retained
TriggerDeviceRebootWithNet‐
work
Additional func‐
tion
BOOL
Restart device com‐
pletely
Restarts the device and
the network stack. The
internal switch function
is interrupted.
0 = no restart
Parameter with
implication for
the safety func‐
tion
0-1-0 = device
restart
(duration of sta‐
tus 1 ≥ 120 ms)
1 = ignored
TriggerDeviceRebootWithout‐
Network
Additional func‐
tion
BOOL
Restarting safety func‐
tion and connections
Restarts the device
without ending the net‐
work stack. The internal
switch function is not
interrupted.
0 = no restart
Parameter with
implication for
the safety func‐
tion
0-1-0 = device
restart
(duration of sta‐
tus 1 ≥ 120 ms)
1 = ignored
TECHNICAL DATA
13
8027931/2022-10-24 | SICK
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 – PROFINET
145