Name
Use
Data type
Definition
Values
Safety implica‐
tion
TriggerResetCutOffPath01
BOOL
Reset Cut-off path 01
Reset of cut-off path 01
after activation of the
restart interlock
Safety-relevant
parameter
0-1-0 = reset
(duration of sta‐
tus 1 ≥ 60 ms)
TriggerResetCutOffPath02
…
TriggerResetCutOffPath08
BOOL
Reset Cut-off path 02
… 08
Reset of cut-off path 02
… 08 after activation of
the restart interlock
1)
Safety-relevant
parameter
0-1-0 = reset
(duration of sta‐
tus 1 ≥ 60 ms)
TriggerRunMode
BOOL
Restarts the safety
function, e.g. if it
was stopped or after
an application error.
(The device must be
restarted after a device
error.)
0 = no start com‐
mand
Safety-relevant
parameter
0-1-0 = start
safety function
(duration of sta‐
tus 1 ≥ 120 ms)
1 = ignored
1)
Cut-off paths 5 to 8 are only available for the Pro performance package.
13.6.1.1.2
Output of the device (input of the control)
Table 40: Output of the device (input of the control)
Name
Use
Data type
Definition
Values
Safety implica‐
tion
ApplicationError
Diagnostics
BOOL
Application error
Signals whether an
application error is
present, causing the
safety function to be
paused. To resolve this,
rectify the cause of the
error and then restart
the safety function.
0 = no applica‐
tion error
Parameter with‐
out safety impli‐
cation
1 = application
error
ContaminationError
Diagnostics
BOOL
Contamination error
Optics cover is dirty. All
safety outputs in the
OFF state. Clean the
optics cover.
0 = no contami‐
nation error
Parameter with
implication for
the safety func‐
tion
1 = contamina‐
tion error
ContaminationWarning
Diagnostics
BOOL
Contamination warning
Optics cover is dirty.
Clean the optics cover.
0 = no contami‐
nation warning
Parameter with‐
out safety impli‐
cation
1 = contamina‐
tion warning
CurrentMonitoringCaseNoTa‐
ble1
Diagnostics
USINT
Current monitoring
case (Monitoring case
table 1)
Signals the current
(active) monitoring case
of monitoring case
table 1.
0 = no monitor‐
ing case is active
Parameter with‐
out safety impli‐
cation
1 … 254 = num‐
ber of the current
(active) monitor‐
ing case
13
TECHNICAL DATA
146
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 – PROFINET
8027931/2022-10-24 | SICK
Subject to change without notice