When the startup process is finished, the status LEDs and the display show the current
operational status.
1
2
3
4
Figure 63: Status LEDs
Table 17: Status LEDs
Number
Function
Color
Meaning
1
Red
Lights up red when at least one
safety output is in the OFF state.
2
Green
Lights up green when at least one
safety output is in the ON state.
3
Yellow
Lights up yellow if an object is
detected in at least one warning
field.
4
Yellow
Setup with reset: Flashes if the
restart interlock has been triggered.
Configuration with automated restart
after a time: Lights up while the con‐
figured time to restart expires.
The OFF state and ON state light emitting diodes can be found in multiple locations on
the device. 3 additional sets are arranged in pairs on the base of the optics cover. So
the LEDs can also be seen in many cases when it is not possible to see the display, e.g.
due to the mounting situation or because it is hidden from the operator’s position.
The device has different LEDs for every network interface. These network LEDs are
located below the display.
More information about what the LEDs mean and the symbols and information shown
on the display:
see "Troubleshooting", page 124
8.4
Check during commissioning and modifications
The thorough check is intended to ensure that the safety functions are fulfilling their
planned purpose and whether persons are being adequately protected.
b
Carry out the checks specified in the test plan of the manufacturer of the machine
and the operating entity.
8
COMMISSIONING
112
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 – PROFINET
8027931/2022-10-24 | SICK
Subject to change without notice