
7.19.2
Factory settings
Overview
Before reconfiguring the device, you can reset all settings to factory settings.
Resetting safety function to factory settings
•
The configuration for the safety function is reset to factory settings.
•
Communication beyond the device is not impaired.
Resetting safety function and communication settings to factory settings
•
The configuration for the safety function is reset to factory settings.
•
The configuration of device communication is reset to factory settings (connec‐
tions for configuration, safety function and data not relating to safety).
Resetting complete settings to factory settings
•
The configuration for the safety function is reset to factory settings.
•
The configuration of device communication is reset to factory settings (connec‐
tions for configuration, safety function and data not relating to safety).
•
The
Maintenance personnel
and
Authorized client
user groups are deactivated.
•
The password of the
Administrator
user group is reset to the factory settings.
7.19.3
Managing passwords
Assigning or changing passwords
1.
Establish a connection to the device.
2.
In the device window under
Service
, select the
User password
entry.
3.
In the
User password
dialog, select the user group.
4.
Enter the new password twice and confirm with
Transfer to device
.
5.
When you are prompted to log on, select your user group and enter the corre‐
sponding password.
✓
The new password is valid for the user group immediately.
Resetting a password
Reset user group password
Administrator
:
1.
Request the form for resetting your password from SICK support.
2.
Connect to the device in Safety Designer.
3.
In the device window under
Service
, select the
User password
entry.
4.
In the
User password
dialog, select the
Start process for resetting the password
option.
5.
Send the information displayed on the form to SICK support.
✓
You will then receive an activation code.
6.
If the device is connected via network: Release the password reset using the OK
button in the corresponding display menu.
7.
Enter and confirm the activation code in the field provided in Safety Designer.
✓
The password of the
Administrator
user group is reset to factory settings (SICK‐
SAFE). The
Maintenance personnel
and
Authorized client
user groups are deactivated.
The configuration is not changed.
7.19.4
Access management
Overview
You can activate or deactivate interfaces and selected functions as needed.
In the
Projected device
area, you can see the settings in the project.
When a device is connected, in the
Physical device
area, you can see the configuration in
the device, the default setting of the device and the result of how the device behaves.
Older devices may not support all settings.
CONFIGURATION
7
8027931/2022-10-24 | SICK
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 – PROFINET
107
Subject to change without notice