outdoorScan3 Pro – PROFINET
Distance between center
point of scan plane and top
edge of the housing
40 mm
Multiple sampling
2 … 16
1)
1)
Can be adjusted collectively for all fields or individually for each field.
Safety-related parameters
Table 31: Safety-related parameters
outdoorScan3 Pro – PROFINET
Type
Type 3 (IEC 61496)
Safety integrity level
SIL 2 (IEC 61508)
SIL claim limit
SILCL 2 (IEC 62061)
Category
Category 3 (ISO 13849-1)
Performance level
PL d (ISO 13849-1)
Performance class SRS/
SRSS
Performance class D (IEC/TS 62998)
PFH
D
(mean probability of a
dangerous failure per hour)
8 × 10
–8
T
M
(mission time)
20 years (ISO 13849-1)
Safe status when a fault
occurs
The safety outputs via the network are logic 0.
Interfaces
Table 32: Interfaces
outdoorScan3 Pro – PROFINET
Safety outputs via network
Quantity
Devices with a max. protec‐
tive field range of 4.0 m
8
Duration of OFF state
≥ 80 ms
Automated restart after
2 s to 60 s (can be configured)
Voltage supply
Connection type
Male connector, M12, 4-pin, A-coded
Length of cable (power supply unit tolerance ± 5%)
Length of cable with wire
cross-section 0.25 mm
²
≤ 100 m
Configuration and diagnostic interface
Type of interface
USB 2.0
Connection type
USB 2.0 mini-B (female connector)
Transmission rate
≤ 12 Mbit/s
Length of cable
≤ 5 m
Fieldbus/industrial network
Type of fieldbus integration
PROFINET PROFIsafe
Connection type
M12 female connector, 4-pin, D-coded
13
TECHNICAL DATA
138
O P E R A T I N G I N S T R U C T I O N S | outdoorScan3 – PROFINET
8027931/2022-10-24 | SICK