e) Torque adjustment
On the main screen, press button
(Fig. 6-22); the
torque adjustment screen is displayed (Fig. 7).
Program the torque using the numeric keypad (Fig. 7-
31).
The programmed torque is displayed (Fig. 7-27).
Press button
(Fig. 7-29) to delete the last digit.
Press button
(Fig. 7-28) to return to the main
screen without saving the changes.
Confirm the torque adjustment by pressing button
(Fig. 7-30); the main screen is displayed.
Note
: The instrument torque can be adjusted directly
using buttons
or
(Fig. 3-6 and 3-7) for
program
, even when the multifunction
footswitch is switched on.
f) Selecting footswitch type
Change the footswitch type if necessary by pressing
button
(Fig. 3-10) to toggle between ON/OFF
and progressive
.
g) Light
If necessary, select light function ON/OFF by pressing
button (Fig.
3-11).
h) Completion of setting adjustment
Confirm the new settings by pressing button
(Fig.
3-8).
The storing of the various settings is confirmed by an
audible signal.
Repeat this sequence if necessary in order to adjust
all the programs.
7. 6 PIEZOTOME FUNCTION
Important:
The P
IEZOTOME
function settings can be customized
by the user.
The P
IEZOTOME
function settings can be adjusted
when no P
IEZOTOME
2 handpiece is connected to the
device.
The program giving the highest power is D1.
Select the Piezotome function by pressing button
(Fig. 3-12) or by pressing the footswitch
button (Fig. 11-5).
On the LCD screen, the P
IEZOTOME
tab must be
highlighted.
Select the program to be used by pressing button
,
,
or
(Fig. 4-14) or using
the footswitch button (Fig. 11-3); the selected
program is highlighted on the LCD screen.
Adjust the programs and the power level according to
the tip data sheet recommendations.
If necessary, modify the irrigation function (flow rate
value, etc.) (refer to 7.3).
If necessary, modify the program power level (1 to 5)
using buttons
(Fig. 3-6) and
(Fig. 3-7).
The power level of the program concerned is shown
as a number and a bar-graph
(Fig. 4-13).
Modify the footswitch type if necessary by pressing
button
(Fig. 3-10) to toggle between ON/OFF
Program
Main functions
Very powerful
D1
Osteotomy, osteoplasty
Powerful
D2
Medium
D3
Low
D4
Soft tissue detachment
Summary of Contents for Implant Center 2
Page 2: ...2 ...
Page 29: ...29 ...
Page 55: ...55 ...
Page 81: ...81 ...
Page 107: ...107 ...
Page 133: ...133 ...
Page 159: ...159 ...
Page 185: ...185 ...
Page 211: ...211 ...
Page 237: ...237 ...
Page 244: ...244 15 16 Fig Afbeelding 5 13 14 Fig Afbeelding 4 ...
Page 245: ...245 20 21 22 23 19 18 24 17 Fig Afbeelding 6 25 26 27 28 29 30 31 Fig Afbeelding 7 ...
Page 246: ...246 41 Fig Afbeelding 9 38 39 40 32 33 34 35 36 37 Fig Afbeelding 8 ...
Page 247: ...247 43 44 45 42 48 49 50 46 47 52 51 Fig Afbeelding 10 1 3 4 5 2 Fig Afbeelding 11 ...