70
Rockwell Automation Publication 2093-AP001A-EN-P - May 2014
Appendix D
Interconnect Diagrams
Figure 13 - Kinetix 5500 Servo Drives with Shared DC (common bus)
Figure 14 - Kinetix 5500 Servo Drives with Shared AC/DC Hybrid Bus
L3
L2
L1
4
3
2
1
L3
L2
L1
L3
L2
L1
24V_COM
+24V
2
1
24V_COM
+24V
24V_COM
+24V
DC+
DC-
DC+
DC-
DC+
DC-
195…264V AC rms or
324…528V AC rms
Three-phase Input
Bonded Cabinet Ground Bus *
Control Power
(CP) Connectors
Three-phase Input
(IPD) Connector
2198-DB
xx
-F
Three-phase
AC Line Filter
* INDICATES USER SUPPLIED COMPONENT
Chassis
Customer Supplied
+24V DC
Power Supply *
DC Bus
(DC) Connectors
2198-Hxxx-ERSx
Kinetix 5500
Servo Drive
2198-Hxxx-ERSx
Kinetix 5500
Servo Drive
2198-Hxxx-ERSx
Kinetix 5500
Servo Drive
PE Ground
PE Ground
PE Ground
Input Fusing *
2198-H0
x
0-ADP-IN
Bus Bar Connectors
2198-H0
x
0-DP-T
Bus Bar Connectors
2198-H0
x
0-DP-T
Bus Bar Connectors
L3
L2
L1
4
3
2
1
L3
L2
L1
L3
L2
L1
24V_COM
+24V
2
1
24V_COM
+24V
24V_COM
+24V
DC+
DC-
DC+
DC-
DC+
DC-
195…264V AC rms or
324…528V AC rms
Three-phase Input
Bonded Cabinet Ground Bus *
Control Power
(CP) Connectors
Three-phase Input
(IPD) Connector
* INDICATES USER SUPPLIED COMPONENT
Chassis
Customer Supplied
+24V DC
Power Supply *
DC Bus
(DC) Connectors
2198-Hxxx-ERSx
Kinetix 5500
Servo Drive
2198-Hxxx-ERSx
Kinetix 5500
Servo Drive
2198-Hxxx-ERSx
Kinetix 5500
Servo Drive
PE Ground
PE Ground
PE Ground
Input Fusing *
2198-DB
xx
-F
Three-phase
AC Line Filter
2198-H0
x
0-ADP-IN
Bus Bar Connectors
2198-H0
x
0-ADP-T
Bus Bar Connectors
2198-H0
x
0-DP-T
Bus Bar Connectors
Summary of Contents for Allen-Bradley Kinetix 2000
Page 1: ...Kinetix 2000 Multi axis Servo Drives to Kinetix 5500 Servo Drives Migration Guide...
Page 6: ...6 Rockwell Automation Publication 2093 AP001A EN P May 2014 Table of Contents...
Page 12: ...12 Rockwell Automation Publication 2093 AP001A EN P May 2014 Preface Notes...
Page 62: ...62 Rockwell Automation Publication 2093 AP001A EN P May 2014 Appendix C Specifications Notes...
Page 75: ......