10
Options: Setra Pressure Transducer (350734)
Ontrac Installation Manual
Begin Installation:
1. Verify analog 2 jumper configuration.
2. Disconnect the battery cable from the RTU Board.
3. Install Transducer to the water pipe. If necessary tee it into the water pipe. (fitting size is 1/8” NPT)
4. Bring the transducer wire harness with strain relief into the Ontrac unit.
5. To wire the Pressure Transducer into the RTU board;
A. Wire into Analog Input 2.
a. Connect the black wire from transducer to the black terminal.
b. Connect the green wire from transducer to the white terminal.
c. Connect the red wire from transducer to the red terminal.
d. White wire will not be used.
6. Hardware install is complete.
7. Go back to installation instructions for the Ontrac unit that is being installed.
8. BEFORE LEAVING THE FIELD, COMPLETE VERIFICATION PROCEDURE BELOW
VERIFICATION:
1. Use internet access
/field_test and radio number to verify communication
http://admin.ontracbyreinke.com
and input status.
2. Make sure Orbcomm Pressure shows up on the test site.
3. Compare the raw number status to pressure (keep in mind the approximate scale)
PSI=Raw No. x .39101 - 40
4. Run the pivot with and without water pressure to verify the transducer is working
correctly.
5. If questions or concerns arise contact technical support.
6. Verification is complete.
204
102
306
40 PSI
0 PSI
80 PSI
409
120 PSI
511
613
160 PSI
200 PSI
Approximate scale
Raw No. Pressure
Summary of Contents for Ontrac
Page 1: ...Ontrac Remote Management Installation Manual Ontrac Installation and Service Manual ...
Page 5: ...Safety Decals located on Main Control Panel preface System Safety IV Ontrac System Safety ...
Page 14: ...87 Satellite Base Units ...
Page 19: ...92 ...
Page 20: ...93 ...
Page 29: ...102 ...
Page 30: ...103 ...
Page 41: ...114 ...
Page 42: ...115 ...
Page 46: ......
Page 51: ...5 ...
Page 52: ......
Page 57: ...10 ...
Page 58: ......
Page 63: ...15 ...
Page 64: ......
Page 72: ......
Page 78: ......
Page 79: ...5 ...
Page 80: ...6 ...
Page 83: ...9 Options Setra Pressure Transducer 350734 Ontrac Installation Manual ...
Page 86: ...12 Options Setra Pressure Transducer Retro Fit 350734R Ontrac Installation Manual ...
Page 95: ...Ontrac Installation Manual 25 Options Post Tower Mount with Stop Iridium 350753 ...
Page 101: ...Ontrac Installation Manual 31 Options Post Tower Mount with Start Stop Iridium 350754 ...
Page 102: ......
Page 120: ...Ontrac Installation Manual 17 Cell Option Wire Theft Retro 356901R SAMPLE ...
Page 130: ...27 Wiring Diagram Ontrac Cell GPS Navigator Cable Ontrac Cell GPS Navigator Cable ...
Page 132: ......
Page 139: ...Moved to Archive Manual 01 2014 Ontrac Installation Manual Troubleshooting ...
Page 142: ...Flowcharts Ontrac Installation Manual Enclosed Adjustable Power Supply Troubleshooting 12 ...
Page 143: ...Ontrac Installation Manual Flowcharts Open Face Power Supply Troubleshooting 13 ...
Page 144: ...Ontrac Installation Manual Solar Panel Troubleshooting 14 Flowcharts ...
Page 145: ...Ontrac Installation Manual Rain Gauge Troubleshooting 15 Flowcharts ...
Page 146: ...Ontrac Installation Manual 16 Flowcharts Flowchart removed 01 14 see Archive Manual on RDSS ...
Page 147: ...Ontrac Installation Manual 17 Flowcharts Setra 1 6v 0 200psi Transducer Troubleshooting ...
Page 148: ...Ontrac Installation Manual Theft Sensor Troubleshooting 18 Flowcharts ...
Page 156: ......
Page 192: ...36 ...
Page 193: ...37 ...
Page 194: ...38 ...
Page 195: ...39 Rain Gauge ...
Page 196: ...40 ...
Page 197: ...41 ...
Page 198: ...Basic 42 ...
Page 199: ...43 ...
Page 200: ...44 ...