Ontrac Installation Manual
Options: Rain Gauge (350740)
Begin Installation:
1. To mount on an Ontrac Post: Mount the rain gauge on the base plate next to the antenna.
2. Remove the cover of the Ontrac Post assembly.
3. Disconnect the battery cable from the RTU Board.
4. Using the strain relief provided route the wire harness into the Ontrac unit.
5. To wire in the Rain Gauge:
A. Wire into Digital Input 4
a. Connect the black wire from the rain gauge to the black terminal.
b. Connect the white wire from rain gauge to the white terminal.
6. Reconnect the RTU board to the battery cable.
7. Hardware installation is complete.
8. If installing on an existing unit proceed to the next step (if not go back to installation instructions).
9. BEFORE LEAVING THE FIELD, COMPLETE VERIFICATION PROCEDURE BELOW
VERIFICATION:
1. Check digital input 4, see if the white terminal reads 5 VDC in normal state and 0 VDC when bucket is
tipped.
2. Use internet access
/field_test and radio number to verify communication
http://admin.ontracbyreinke.com
and input status.
3. Compare the raw number status to the input voltage (keeping in mind 5 VDC is on and 0 VDC is off)
4. If Installing on an existing unit call Reintech at 1-888-872-2360 to complete setup.
5. If questions or concerns arise contact technical support.
6. Verification is complete.
23
Summary of Contents for Ontrac
Page 1: ...Ontrac Remote Management Installation Manual Ontrac Installation and Service Manual ...
Page 5: ...Safety Decals located on Main Control Panel preface System Safety IV Ontrac System Safety ...
Page 14: ...87 Satellite Base Units ...
Page 19: ...92 ...
Page 20: ...93 ...
Page 29: ...102 ...
Page 30: ...103 ...
Page 41: ...114 ...
Page 42: ...115 ...
Page 46: ......
Page 51: ...5 ...
Page 52: ......
Page 57: ...10 ...
Page 58: ......
Page 63: ...15 ...
Page 64: ......
Page 72: ......
Page 78: ......
Page 79: ...5 ...
Page 80: ...6 ...
Page 83: ...9 Options Setra Pressure Transducer 350734 Ontrac Installation Manual ...
Page 86: ...12 Options Setra Pressure Transducer Retro Fit 350734R Ontrac Installation Manual ...
Page 95: ...Ontrac Installation Manual 25 Options Post Tower Mount with Stop Iridium 350753 ...
Page 101: ...Ontrac Installation Manual 31 Options Post Tower Mount with Start Stop Iridium 350754 ...
Page 102: ......
Page 120: ...Ontrac Installation Manual 17 Cell Option Wire Theft Retro 356901R SAMPLE ...
Page 130: ...27 Wiring Diagram Ontrac Cell GPS Navigator Cable Ontrac Cell GPS Navigator Cable ...
Page 132: ......
Page 139: ...Moved to Archive Manual 01 2014 Ontrac Installation Manual Troubleshooting ...
Page 142: ...Flowcharts Ontrac Installation Manual Enclosed Adjustable Power Supply Troubleshooting 12 ...
Page 143: ...Ontrac Installation Manual Flowcharts Open Face Power Supply Troubleshooting 13 ...
Page 144: ...Ontrac Installation Manual Solar Panel Troubleshooting 14 Flowcharts ...
Page 145: ...Ontrac Installation Manual Rain Gauge Troubleshooting 15 Flowcharts ...
Page 146: ...Ontrac Installation Manual 16 Flowcharts Flowchart removed 01 14 see Archive Manual on RDSS ...
Page 147: ...Ontrac Installation Manual 17 Flowcharts Setra 1 6v 0 200psi Transducer Troubleshooting ...
Page 148: ...Ontrac Installation Manual Theft Sensor Troubleshooting 18 Flowcharts ...
Page 156: ......
Page 192: ...36 ...
Page 193: ...37 ...
Page 194: ...38 ...
Page 195: ...39 Rain Gauge ...
Page 196: ...40 ...
Page 197: ...41 ...
Page 198: ...Basic 42 ...
Page 199: ...43 ...
Page 200: ...44 ...