Node Feature Settings Screen (Page 2)
From the CAN Controller Status screen, touch within the Features Settings area to display the first Node
Settings screen and select the
Next
button to access the following alarm and feature settings.
Note:
The following sections offer descriptions of the various options and settings used with liquid
products. For descriptions of the settings used with granular products, see the Feature Settings
Area for Granular Products section on page 144.
Zero Speed Shutoff.
Enable the zero speed shutoff feature to allow the field computer to automatically shut
off product application if the vehicle speed is slower than 0.7 mph [1.1 km/h]. If the zero speed shutoff feature
is engaged during a job, the Viper Pro will also display a zero speed alert.
Note:
The zero speed shutoff feature only affects products set to automatic control. Products controlled
manually will continue to be applied even if the zero speed shutoff feature is engaged.
To restart product application after the zero speed shutoff feature has engaged, cycle the master switch ‘Off’
and then back ‘On.’ The zero speed shutoff feature will reactivate if the vehicle does not achieve a speed
greater than 0.7 MPH [1.1 km/h] and maintain that speed for more than 10 seconds.
Vacuum/Bin Alarm.
The vacuum/bin alarm must be disabled for nodes or channels configured for standard
(non-injection) liquid product application control.
Enable the vacuum alarm feature if an injection pump is controlled via a CAN product control or motor control
node. When activated, the vacuum alarm displays an alert if the injection pump cannot draw product from the
supply tank.
Enable the bin alarm for granular applications if an optional bin level sensor is installed. With this feature
enabled, the Viper Pro will display an alert when the sensor detects the product level in the bin falls below the
sensor level.
Note:
Contact a local Raven dealer for information on injection systems or bin level sensors.
Flow/Shaft Alarm.
Enable the flow/shaft alarm to display an alert if the field computer does not detect a signal
from the pump shaft encoder or flow switch. This alarm may be used to help troubleshoot flow errors with a
CAN motor control node.
Note:
This feature is currently not used with the Raven Sidekick Pro injection system.
Decimal Shift.
Enable the decimal shift feature to increase the system accuracy for low application rates. In
the standard mode, the Viper Pro displays values to one decimal place. With the decimal shift feature enabled,
values will be displayed to two decimal places.
Note:
Verify all calibration values after the decimal shift feature is either enabled or disabled. Change
settings as necessary.
Summary of Contents for OmniSeed Viper Pro
Page 1: ...Viper Pro Software Version 3 10 OmniSeed Calibration Operation Manual ...
Page 10: ...Table of Contents viii OmniSeed Viper Pro Calibration Operation Manual ...
Page 98: ...Chapter 4 86 OmniSeed Viper Pro Installation Operation Manual ...
Page 150: ...Chapter 6 138 OmniSeed Viper Pro Installation Operation Manual ...
Page 222: ...Chapter 10 210 OmniSeed Viper Pro Installation Operation Manual ...
Page 240: ...Chapter 11 228 OmniSeed Viper Pro Installation Operation Manual ...
Page 251: ...Manual No 016 3001 015 Rev C 239 FIGURE 2 OmniSeed System Diagram 3 Bin D N 054 3001 026 ...
Page 256: ...Appendix A 244 OmniSeed Viper Pro Installation Operation Manual ...
Page 284: ...Appendix D 272 OmniSeed Viper Pro Installation Operation Manual ...
Page 292: ...Appendix G 280 OmniSeed Viper Pro Installation Operation Manual ...
Page 300: ...Appendix H 288 OmniSeed Viper Pro Installation Operation Manual ...
Page 304: ...Index 292 OmniSeed Viper Pro Calibration Operation Manual ...
Page 307: ......