4
Manual No. 016-3001-015 Rev. C
49
Initial Set Up and Navigation
3.
Toggle the master switch on.
4.
Use the INC/DEC switch to adjust the roller speed while priming the roller. Be sure that the product being
calibrated is selected before toggling the INC/DEC switch in the application control screen.
5.
When the roller is primed, toggle the master switch off.
6.
Empty the weight box and proceed to the
Catch Test and Cal Weight Calculation
section below to calibrate
product 1. To prime remaining product nodes or control channels, toggle the product 1 switch to off, toggle
the desired product switch to manual and repeat the above process.
Catch Test and Cal Weight Calculation
1.
Set the switch box as follows:
a.
Toggle one section assigned to the product being calibrated to the on position.
b.
Toggle the remaining section switches to the off position.
c.
Master switch off.
d.
Product 1-5 switches off.
2.
Touch within the
Product Control
area at the bottom of the main screen.
3.
Make sure that
Node 1
is selected on the CAN Controller Status screen and touch within the second data
display area, or the Product Control Settings area, on the CAN Controller Status screen.
4.
Touch the
Calibration Assistance
button below the cal weight value. The Cal Weight Calibration screen
will display.
Note:
The application type must be set for Gran 4 in order to use the cal weight calibration assistance
feature. See the Application and Control Valve Type(s) section on page 40 for more information on
selecting the application type.
5.
Verify that the weight box is in place and that no product will be spilled on the ground.
Note:
Make sure the metering roller is full of product before touching
Begin Calibration
. If the roller is
not full, the test results will be inaccurate. Perform the Priming the Metering Rollers section on
page 48 to ensure the rollers are properly primed.
6.
Touch the
Begin Calibration
button.
7.
Toggle the product 1 switch to manual.
8.
Toggle the master switch on.
9.
Dispense product until a sufficient weight of product is in the weight box or the weight box is full.
10.
Toggle the master switch off.
11.
Touch the
End Calibration
button.
WARNING
The metering rollers will begin turning during
the priming procedure. Keep away from moving
components and alert anyone around the air
cart when performing the priming process.
WARNING
The metering rollers will begin turning during
the calibration procedure. Keep away from
moving components and alert anyone around
the air cart when performing the calibration
process.
Summary of Contents for OmniSeed Viper Pro
Page 1: ...Viper Pro Software Version 3 10 OmniSeed Calibration Operation Manual ...
Page 10: ...Table of Contents viii OmniSeed Viper Pro Calibration Operation Manual ...
Page 98: ...Chapter 4 86 OmniSeed Viper Pro Installation Operation Manual ...
Page 150: ...Chapter 6 138 OmniSeed Viper Pro Installation Operation Manual ...
Page 222: ...Chapter 10 210 OmniSeed Viper Pro Installation Operation Manual ...
Page 240: ...Chapter 11 228 OmniSeed Viper Pro Installation Operation Manual ...
Page 251: ...Manual No 016 3001 015 Rev C 239 FIGURE 2 OmniSeed System Diagram 3 Bin D N 054 3001 026 ...
Page 256: ...Appendix A 244 OmniSeed Viper Pro Installation Operation Manual ...
Page 284: ...Appendix D 272 OmniSeed Viper Pro Installation Operation Manual ...
Page 292: ...Appendix G 280 OmniSeed Viper Pro Installation Operation Manual ...
Page 300: ...Appendix H 288 OmniSeed Viper Pro Installation Operation Manual ...
Page 304: ...Index 292 OmniSeed Viper Pro Calibration Operation Manual ...
Page 307: ......