![Raven OmniSeed Viper Pro Calibration & Operation Manual Download Page 105](http://html.mh-extra.com/html/raven/omniseed-viper-pro/omniseed-viper-pro_calibration-and-operation-manual_788947105.webp)
5
Manual No. 016-3001-015 Rev. C
93
Using the OmniSeed Viper Pro System
Assigning Recommendations
Note:
While recommendations are not required, product control channels selected on this screen should
have a recommendation assigned before the job is started. A single recommendation may be
assigned to multiple channels if more than one channel will apply the same product.
A target rate may be entered for channels used to control pump, fan, or spinner speeds as
necessary after the job is started. Do not select control channels for these functions during the job
setup process.
2.
Touch the recommendation for the product to be applied using the selected control channel. A red box will
display around the selected recommendation and the preview information will be displayed.
3.
Select other channels and assign recommendations as the job requires.
Note:
A recommendation assigned to a different product channel will display a green check mark to the
right of the recommendation name. The red box and preview information will only display if the
recommendation is assigned to the selected channel.
4.
Confirm the section assignments, default rate and conversion factor settings are correct for each product
channel before touching the
Next
button to continue the job set up. Refer to the following sections for
details on these settings.
Note:
Recommendations may be assigned to any product during the job setup. During the job, Viper Pro
will display any “skipped” control channels and the operator may control application of a product
using these channels if necessary. “Skipped” channels will not have a product name associated
with the control channel and the application report will need to be adjusted for these skipped
products.
It is recommended to assign recommendations to any control channels to be used during an active
job in sequential order to avoid “skipped” channels whenever possible.
Booms
Sections assigned to the selected channel can be changed by touching the
Booms
button at the bottom of the
screen.
Confirm the boom or section selections are correctly set up for the equipment being used.
Note:
The boom or section selections are also accessible before setting up a job through the Product
Control area on the Viper Pro Main screen. Refer to the Section Setup section on page 53 for
more information.
Default Rate
Touch the
Default Rate
button to enter a standard rate of application for the channel when no prescription
information is available. The default rate only affects areas where prescription rate information has not been
entered.
Note:
Zero rate zones will not be affected by the default rate setting.
Summary of Contents for OmniSeed Viper Pro
Page 1: ...Viper Pro Software Version 3 10 OmniSeed Calibration Operation Manual ...
Page 10: ...Table of Contents viii OmniSeed Viper Pro Calibration Operation Manual ...
Page 98: ...Chapter 4 86 OmniSeed Viper Pro Installation Operation Manual ...
Page 150: ...Chapter 6 138 OmniSeed Viper Pro Installation Operation Manual ...
Page 222: ...Chapter 10 210 OmniSeed Viper Pro Installation Operation Manual ...
Page 240: ...Chapter 11 228 OmniSeed Viper Pro Installation Operation Manual ...
Page 251: ...Manual No 016 3001 015 Rev C 239 FIGURE 2 OmniSeed System Diagram 3 Bin D N 054 3001 026 ...
Page 256: ...Appendix A 244 OmniSeed Viper Pro Installation Operation Manual ...
Page 284: ...Appendix D 272 OmniSeed Viper Pro Installation Operation Manual ...
Page 292: ...Appendix G 280 OmniSeed Viper Pro Installation Operation Manual ...
Page 300: ...Appendix H 288 OmniSeed Viper Pro Installation Operation Manual ...
Page 304: ...Index 292 OmniSeed Viper Pro Calibration Operation Manual ...
Page 307: ......