Appendix B
262
OmniSeed™ Viper Pro™ Installation & Operation Manual
10.
Dispense exactly 10 gallons [38 L] through the flow meter as measured by the calibrated catch container.
Important:
Do not rely on graduation markings/numbers molded into the applicator tank.
11.
Toggle the section or master switch off.
12.
Read the value displayed on the field computer Total Volume button. This value should be within ± 3% of the
meter cal value printed on the flow meter tag.
13.
To confirm accuracy, reset the Total Volume to 0 and repeat the above process several times. Always ‘zero
out’ the Total Volume display before toggling the section switch on.
Note:
The above process is usually sufficient to check the flow meter calibration. For best results, set the
Meter Cal value to 100 [378] and repeat the above procedure to dispense exactly 100 gallons [378
L] through the flow meter.
To verify the flow meter calibration:
1.
Fill the applicator tank with a predetermined volume of liquid (i.e. 250 gallons [946 L]).
Important:
Do not rely on graduation markings/numbers molded into the applicator tank.
1.
On the field computer Home screen, touch the Tools Menu icon.
2.
Select the Product Control icon from the System menu.
3.
On the Product Control Configuration screen, touch the Volume/Area Settings button.
4.
Use the on-screen keypad to enter a value of 0 and touch the Accept icon.
5.
Empty the applicator tank under normal operating conditions.
6.
Return to the Total Volume displayed on the field computer and read the new value. The total volume value
should match the known volume (± 3%) used to fill the applicator tank.
7.
If the total volume value displayed differs from the known volume by greater than 3%, use the following
formula
Where MC = the Meter Cal value used during the test, Vm = the Volume measured by the field computer,
Vk = the known Volume in the applicator tank and CMC = the Corrected Meter Cal.
For Example:
A set meter cal of 720 [190] is used to dispense 250 gallons [946 L] through the flow meter. At the end of the
test, the field computer reads a measured volume of 260 gallons [984 L]:
or
Therefore, the corrected meter cal is 749 [198].
8.
Enter the corrected meter cal value before resuming application.
MC
Vm
×
Vk
------------------------
CMC
=
720
260
×
250
------------------------
749
=
190
[
]
984
[
]
×
946
[
]
----------------------------------
198
[
]
=
Summary of Contents for OmniSeed Viper Pro
Page 1: ...Viper Pro Software Version 3 10 OmniSeed Calibration Operation Manual ...
Page 10: ...Table of Contents viii OmniSeed Viper Pro Calibration Operation Manual ...
Page 98: ...Chapter 4 86 OmniSeed Viper Pro Installation Operation Manual ...
Page 150: ...Chapter 6 138 OmniSeed Viper Pro Installation Operation Manual ...
Page 222: ...Chapter 10 210 OmniSeed Viper Pro Installation Operation Manual ...
Page 240: ...Chapter 11 228 OmniSeed Viper Pro Installation Operation Manual ...
Page 251: ...Manual No 016 3001 015 Rev C 239 FIGURE 2 OmniSeed System Diagram 3 Bin D N 054 3001 026 ...
Page 256: ...Appendix A 244 OmniSeed Viper Pro Installation Operation Manual ...
Page 284: ...Appendix D 272 OmniSeed Viper Pro Installation Operation Manual ...
Page 292: ...Appendix G 280 OmniSeed Viper Pro Installation Operation Manual ...
Page 300: ...Appendix H 288 OmniSeed Viper Pro Installation Operation Manual ...
Page 304: ...Index 292 OmniSeed Viper Pro Calibration Operation Manual ...
Page 307: ......