![Raven OmniSeed Viper Pro Calibration & Operation Manual Download Page 159](http://html.mh-extra.com/html/raven/omniseed-viper-pro/omniseed-viper-pro_calibration-and-operation-manual_788947159.webp)
Manual No. 016-3001-015 Rev. C
147
Advanced Settings and Features
7
Display Smoothing.
Enable the display smoothing feature to allow the field computer to smooth the rate
displayed during product applications. With this feature enabled, the actual rate (R
A
) in the rates area will
display the target rate (R
T
) as long as the actual monitored application rate remains within ±10% of the target
rate. The actual rate shown on the main screen will display the actual monitored rate if the application system
does not reach the target rate dead band (±10%) within 10 seconds.
Disable the display smoothing feature to monitor the actual application rate at all times.
Note:
The display smoothing feature is only active for products in Automatic control mode.
Feature Settings Area for Liquid Products
The information displayed in the Feature Settings area is an overview of the alarm and feature settings for the
selected product control node. For liquid products, the following settings will be displayed in the Feature
Settings area:
Note:
The following sections offer descriptions of the various options and settings used with liquid
products. For descriptions of the settings used with granular products, see the Feature Settings
Area for Granular Products section on page 144.
If the OmniSeed system will be used with a Raven AccuFlow™ system, the anhydrous system
must be assigned to product channel 4 on the Viper Pro to ensure valve shut off is performed
correctly using the switch box inputs.
•
Dual Flow %/FER Cal
•
Vacuum/Bin Alarm
•
Low PSI Alarm
•
Off Rate %
•
Decimal Shift
•
Max PSI Alarm
•
Low Tank
•
Zero Speed Shutoff
•
Standby Pressure
Enable
•
Low Limit
•
Display Smoothing
•
Dual Loop Control
•
Flow/Shaft Alarm
•
Agitator
•
Smart Control
•
Ratio Rate
Summary of Contents for OmniSeed Viper Pro
Page 1: ...Viper Pro Software Version 3 10 OmniSeed Calibration Operation Manual ...
Page 10: ...Table of Contents viii OmniSeed Viper Pro Calibration Operation Manual ...
Page 98: ...Chapter 4 86 OmniSeed Viper Pro Installation Operation Manual ...
Page 150: ...Chapter 6 138 OmniSeed Viper Pro Installation Operation Manual ...
Page 222: ...Chapter 10 210 OmniSeed Viper Pro Installation Operation Manual ...
Page 240: ...Chapter 11 228 OmniSeed Viper Pro Installation Operation Manual ...
Page 251: ...Manual No 016 3001 015 Rev C 239 FIGURE 2 OmniSeed System Diagram 3 Bin D N 054 3001 026 ...
Page 256: ...Appendix A 244 OmniSeed Viper Pro Installation Operation Manual ...
Page 284: ...Appendix D 272 OmniSeed Viper Pro Installation Operation Manual ...
Page 292: ...Appendix G 280 OmniSeed Viper Pro Installation Operation Manual ...
Page 300: ...Appendix H 288 OmniSeed Viper Pro Installation Operation Manual ...
Page 304: ...Index 292 OmniSeed Viper Pro Calibration Operation Manual ...
Page 307: ......