![Raven OmniSeed Viper Pro Calibration & Operation Manual Download Page 220](http://html.mh-extra.com/html/raven/omniseed-viper-pro/omniseed-viper-pro_calibration-and-operation-manual_788947220.webp)
Chapter 10
208
OmniSeed™ Viper Pro™ Installation & Operation Manual
Sensitivity.
Use the sensitivity value to set the approximate number of seeds per second which each sensor in
the loop should detect when the system is operating normally. If a sensor does not detect the set value for
seeding rates, the system will display a blockage or obstruction and indicate which sensor is detecting the
error. The default sensitivity value is 15.
To adjust the sensitivity, either:
•
Touch the current sensitivity value and use the keypad at the bottom of the screen to enter a new sensitivity
value, or
•
Use the up or down arrows to the right of the sensitivity value to increase or decrease the sensitivity value in
smaller increments.
Status.
The status indicator displays the status of seed or product flow in the seed tubes. The seed blockage
status will display:
Green when the system is operating normally.
Yellow when a product blockage or dirty sensor is detected in the system. Check the indicated sensor
locations in the
display and clear any obstructions as necessary during operation.
Red if a communication issue is detected with the seed blockage sensors. Check sensor assemblies
and cables for disconnected or damaged parts and replace parts as necessary.
Note:
The seed blockage sensor status area on the main screen will provide the same status displays for
each sensor loop as described above to allow the operator to monitor the seed blockage system
throughout the seeding operation.
Sensor Count.
Check that the programmed sensor count for loop 1 and loop 2 matches the number of
sensors installed on the drill. To adjust the number of sensors, refer to the
Blocked.
When a blockage is detected in loop 1 or loop 2, the sensor number(s) which detect an obstruction or
blockage will be displayed in this area. Check these sensor locations for obstructions in the line to clear the
blockage condition.
Note:
To help locate blockages during operation more quickly, it is recommended to number the sensors.
Refer to the seed blockage sensor installation instructions for details on numbering the sensors.
Dirty.
Sensors may need to be cleaned periodically during seeding operations to ensure that the system is
accurately detecting the flow of seed or product through seed tubes. Check and clean the indicated
sensor(s) to ensure optimal system performance.
When monitoring particularly dirty seed types or products, it may be necessary to clean each sensor in the
loop when a the system indicates a sensor or sensors in the loop are dirty.
Audible Blockage Alarm.
Enable this option to receive and audible warning or alert when the blockage status
changes from a normal condition.
Summary of Contents for OmniSeed Viper Pro
Page 1: ...Viper Pro Software Version 3 10 OmniSeed Calibration Operation Manual ...
Page 10: ...Table of Contents viii OmniSeed Viper Pro Calibration Operation Manual ...
Page 98: ...Chapter 4 86 OmniSeed Viper Pro Installation Operation Manual ...
Page 150: ...Chapter 6 138 OmniSeed Viper Pro Installation Operation Manual ...
Page 222: ...Chapter 10 210 OmniSeed Viper Pro Installation Operation Manual ...
Page 240: ...Chapter 11 228 OmniSeed Viper Pro Installation Operation Manual ...
Page 251: ...Manual No 016 3001 015 Rev C 239 FIGURE 2 OmniSeed System Diagram 3 Bin D N 054 3001 026 ...
Page 256: ...Appendix A 244 OmniSeed Viper Pro Installation Operation Manual ...
Page 284: ...Appendix D 272 OmniSeed Viper Pro Installation Operation Manual ...
Page 292: ...Appendix G 280 OmniSeed Viper Pro Installation Operation Manual ...
Page 300: ...Appendix H 288 OmniSeed Viper Pro Installation Operation Manual ...
Page 304: ...Index 292 OmniSeed Viper Pro Calibration Operation Manual ...
Page 307: ......