![Raven OmniSeed Viper Pro Calibration & Operation Manual Download Page 201](http://html.mh-extra.com/html/raven/omniseed-viper-pro/omniseed-viper-pro_calibration-and-operation-manual_788947201.webp)
8
Manual No. 016-3001-015 Rev. C
189
OmniSeed Section Control
Automatic Section Control Override Sec
The automatic section control Override feature allows the operator to momentarily apply product to a
previously applied area while in a job. The override feature is useful to ensure product application in small
unapplied areas near irregular headlands and previously applied areas. Enter the number of seconds to
override automatic section control and apply product after the master switch is toggled to the ‘OVERRIDE’
position.
Note:
The time set as the override seconds does not start until the master switch returns to the on
position. Hold the master switch in the override position to sustain the override countdown if
desired.
Turn-Off % Coverage
This value controls the percentage of the section width that must be inside a previously applied area in order
for the section to turn off. The default value is 80%. This would require that 80% of a section be in a previously
applied area before the OmniSeed system would turn off that section.
Note:
If the value is set to 0%, the section will not turn off automatically.
Configuring Automatic Section Control
1.
Touch the
Section Status
area in the main Viper screen. The Section Control Setup screen displays.
2.
Using the screen keyboard, enter a value, in seconds, in the ‘
Turn-On
’
Look-Ahead
field.
3.
Using the screen keyboard, enter a value, in seconds, in the ‘
Turn-Off’ Look-Ahead
field.
4.
Using the screen keyboard, enter a value, in percentage, in the ‘
Turn-Off
’
% Coverage
field.
5.
Using the screen keyboard, enter a value, if desired, in seconds, in the
Section Control Override Sec
field.
Summary of Contents for OmniSeed Viper Pro
Page 1: ...Viper Pro Software Version 3 10 OmniSeed Calibration Operation Manual ...
Page 10: ...Table of Contents viii OmniSeed Viper Pro Calibration Operation Manual ...
Page 98: ...Chapter 4 86 OmniSeed Viper Pro Installation Operation Manual ...
Page 150: ...Chapter 6 138 OmniSeed Viper Pro Installation Operation Manual ...
Page 222: ...Chapter 10 210 OmniSeed Viper Pro Installation Operation Manual ...
Page 240: ...Chapter 11 228 OmniSeed Viper Pro Installation Operation Manual ...
Page 251: ...Manual No 016 3001 015 Rev C 239 FIGURE 2 OmniSeed System Diagram 3 Bin D N 054 3001 026 ...
Page 256: ...Appendix A 244 OmniSeed Viper Pro Installation Operation Manual ...
Page 284: ...Appendix D 272 OmniSeed Viper Pro Installation Operation Manual ...
Page 292: ...Appendix G 280 OmniSeed Viper Pro Installation Operation Manual ...
Page 300: ...Appendix H 288 OmniSeed Viper Pro Installation Operation Manual ...
Page 304: ...Index 292 OmniSeed Viper Pro Calibration Operation Manual ...
Page 307: ......