![Raven OmniSeed Viper Pro Calibration & Operation Manual Download Page 115](http://html.mh-extra.com/html/raven/omniseed-viper-pro/omniseed-viper-pro_calibration-and-operation-manual_788947115.webp)
5
Manual No. 016-3001-015 Rev. C
103
Using the OmniSeed Viper Pro System
Bin Level
The level of product remaining in each air cart bin is displayed as a percentage of the total bin height. If the bin
displays “Ready” for the bin level, the ultrasonic sensor may need to be calibrated.
Tank Level
The estimated level of product remaining in a liquid tank is displayed for products controlled by product nodes
4 or 5.
Touch within the Application Rates area to display the Application Control screen.
Use the on-screen keypad on the Application Control screen to enter a target rate and rate bump (-/+) value for
each product.
Note:
If the product switch is in the off position, the product name, target rate, and rate bump (-/+) will
display in grey (product 5 shown above). To modify settings for the product, toggle the product
switch to the Man (manual) or Auto (automatic) position.
Rate Bump (-/+)
The rate bump feature allows the operator to raise or lower the target rate using the INC/DEC switch on the
CAN switch box.
To use the rate bump feature:
1.
Enter a value in the “Rate -/+” field for the desired products. This is the value by which the target rate will be
adjusted each time the INC/DEC switch is toggled.
2.
Select the “Inc/Dec Switch” option for the products to be affected by the INC/DEC switch.
3.
Touch the
OK
button to accept the programmed values and settings and return to the main screen.
4.
Set the product switches to Auto.
5.
Toggle the INC/DEC switch to increase or decrease the target rate of the selected products
Note:
For products set to Manual control mode, hold the INC/DEC switch to manually raise or lower the
target rate.
Summary of Contents for OmniSeed Viper Pro
Page 1: ...Viper Pro Software Version 3 10 OmniSeed Calibration Operation Manual ...
Page 10: ...Table of Contents viii OmniSeed Viper Pro Calibration Operation Manual ...
Page 98: ...Chapter 4 86 OmniSeed Viper Pro Installation Operation Manual ...
Page 150: ...Chapter 6 138 OmniSeed Viper Pro Installation Operation Manual ...
Page 222: ...Chapter 10 210 OmniSeed Viper Pro Installation Operation Manual ...
Page 240: ...Chapter 11 228 OmniSeed Viper Pro Installation Operation Manual ...
Page 251: ...Manual No 016 3001 015 Rev C 239 FIGURE 2 OmniSeed System Diagram 3 Bin D N 054 3001 026 ...
Page 256: ...Appendix A 244 OmniSeed Viper Pro Installation Operation Manual ...
Page 284: ...Appendix D 272 OmniSeed Viper Pro Installation Operation Manual ...
Page 292: ...Appendix G 280 OmniSeed Viper Pro Installation Operation Manual ...
Page 300: ...Appendix H 288 OmniSeed Viper Pro Installation Operation Manual ...
Page 304: ...Index 292 OmniSeed Viper Pro Calibration Operation Manual ...
Page 307: ......