Manual No. 016-3001-015 Rev. C
155
Advanced Settings and Features
7
Valve Delay.
Set the valve delay to include a time delay between when the booms are turned on and when the
product nodes start to control the flow rate. Viper Pro activates this delay if the time between turning the boom
on and off is less than 30 seconds.
Note:
A value of zero must be entered if a Fast Close or PWM Close valve is used as the control valve or
when the Valve Type is programmed as a standard valve with an injection system.
Application Delay.
Not applicable when operating in Gran 4 or Gran 5 modes.
Product Control Settings Area for Liquid Products
The Product Control Settings area displays an overview of the following calibration settings and values used
by the control system to monitor or adjust the rate of product application:
Note:
The following sections offer descriptions of the various options and settings used with liquid
products. For descriptions of the settings used with granular products, see the Product Control
Settings Area for Granular Products section on page 152.
If the OmniSeed system will be used with a Raven AccuFlow™ system, the anhydrous system
must be assigned to product channel 4 on the Viper Pro to ensure valve shut off is performed
correctly using the switch box inputs.
The following data displays are shown in the Product Control Settings area for reference and monitoring
purposes only:
Area/Hour.
Displays the current area per hour covered during product application. This value is calculated
using the programmed section set up and the vehicle speed.
Vol/Min.
Displays the current volume per minute monitored by the selected product node or control channel
during active application. This value is calculated using the flow of product monitored by the flow meter.
PWM.
Displays the current duty cycle of the PWM valve controlling product application (if applicable).
•
Tank Volume
•
Spreader (Constant)
•
Standby Pressure
•
Area/Hour (Display only)
•
Valve Cal
•
Pre Set PW
•
Vol/Min (Display only)
•
Valve Cal 2
•
PW Freq
•
Rate Cal
•
Valve Advance
•
Ratio Rate
•
Rate Bump (+/-)
•
Fan/Pump Cal
•
Valve Delay
•
Meter Cal/Density
•
Min PW
•
PWM (Display only)
•
Max PW
•
Max PSI (not applicable
for granular applications)
Summary of Contents for OmniSeed Viper Pro
Page 1: ...Viper Pro Software Version 3 10 OmniSeed Calibration Operation Manual ...
Page 10: ...Table of Contents viii OmniSeed Viper Pro Calibration Operation Manual ...
Page 98: ...Chapter 4 86 OmniSeed Viper Pro Installation Operation Manual ...
Page 150: ...Chapter 6 138 OmniSeed Viper Pro Installation Operation Manual ...
Page 222: ...Chapter 10 210 OmniSeed Viper Pro Installation Operation Manual ...
Page 240: ...Chapter 11 228 OmniSeed Viper Pro Installation Operation Manual ...
Page 251: ...Manual No 016 3001 015 Rev C 239 FIGURE 2 OmniSeed System Diagram 3 Bin D N 054 3001 026 ...
Page 256: ...Appendix A 244 OmniSeed Viper Pro Installation Operation Manual ...
Page 284: ...Appendix D 272 OmniSeed Viper Pro Installation Operation Manual ...
Page 292: ...Appendix G 280 OmniSeed Viper Pro Installation Operation Manual ...
Page 300: ...Appendix H 288 OmniSeed Viper Pro Installation Operation Manual ...
Page 304: ...Index 292 OmniSeed Viper Pro Calibration Operation Manual ...
Page 307: ......