Manual No. 016-3001-015 Rev. C
145
Advanced Settings and Features
7
Node Feature Settings Screen (Page 1)
Touch within the Feature Settings area to view the first screen of settings for the selected product node or
control channel.
Note:
Touch the
Next
button to access additional alarm and feature settings for the selected product
node or control channel.
Off Rate %.
The off rate percent value sets the allowable difference between the target and actual product
application rates. If a non-zero value is entered for this setting and the difference between target and actual
rate exceeds the set value for longer than five seconds, the Viper Pro will display an off rate alarm. Enter a
value of zero to disable the off rate alarm.
Low Limit.
The low limit value sets the lowest volume per minute acceptable during application of a product. If
the flow rate drops below the low limit value, the field computer will stop closing the control valve and display a
flow alarm.
The field computer automatically adjusts the low limit value for active boom or implement sections. For
example, if a low limit of 4 is entered but only half of the total boom width is currently applying product, the
Viper Pro will only display a flow alarm if the volume per minute drops below 2.
Low Tank.
The low tank value displays an alert when the volume remaining in a tank or bin is reduced to the
entered value. When the calculated volume remaining in the tank or bin is reduced to the entered value, the
Viper Pro will display an alert.
Note:
To utilize the low tank alarm feature, an initial tank or bin volume must be entered for the
corresponding product node or control channel. Refer to Tank Volume section on page 156 for
details on setting the initial tank or bin volume.
The alarm condition is cleared either when all sections are turned off or if a new low tank value less than or
equal to the current calculated tank volume is entered. Enter a value of zero to disable the low tank alarm.
Summary of Contents for OmniSeed Viper Pro
Page 1: ...Viper Pro Software Version 3 10 OmniSeed Calibration Operation Manual ...
Page 10: ...Table of Contents viii OmniSeed Viper Pro Calibration Operation Manual ...
Page 98: ...Chapter 4 86 OmniSeed Viper Pro Installation Operation Manual ...
Page 150: ...Chapter 6 138 OmniSeed Viper Pro Installation Operation Manual ...
Page 222: ...Chapter 10 210 OmniSeed Viper Pro Installation Operation Manual ...
Page 240: ...Chapter 11 228 OmniSeed Viper Pro Installation Operation Manual ...
Page 251: ...Manual No 016 3001 015 Rev C 239 FIGURE 2 OmniSeed System Diagram 3 Bin D N 054 3001 026 ...
Page 256: ...Appendix A 244 OmniSeed Viper Pro Installation Operation Manual ...
Page 284: ...Appendix D 272 OmniSeed Viper Pro Installation Operation Manual ...
Page 292: ...Appendix G 280 OmniSeed Viper Pro Installation Operation Manual ...
Page 300: ...Appendix H 288 OmniSeed Viper Pro Installation Operation Manual ...
Page 304: ...Index 292 OmniSeed Viper Pro Calibration Operation Manual ...
Page 307: ......