Manual No. 016-3001-015 Rev. C
191
OmniSeed Section Control
Switch Box Setup
When used with the OmniSeed system, the Raven CAN switch box must be properly configured to control
granular and liquid sections appropriately. To check the Raven CAN switch box setup:
1.
Touch the Product Control status indicator in the lower, left corner of the main screen.
2.
Touch within the Section Cals area in the upper, left corner of the CAN Controller Status screen. The
Section Select screen will be displayed
Note:
Settings on the Section Select screen are locked during job applications. Be sure the Section
Select screen is properly configured for applications before starting or resuming job applications.
Refer to the
section on page 68 for details on setting the Section Select screen for a
specific implement or drill configuration.
Section Control Aggressiveness Factor
The look-ahead values set the amount of time ahead of the vehicle (based on vehicle speed) which the field
computer will scan for zone boundaries or un-applied areas when turning sections on or off. By default, the
automatic section control feature overrides any additional zone boundaries detected until the look-ahead time
has passed. For example, if the turn-on look-ahead value is set to 5 seconds and system detects an un-applied
area 5 seconds ahead of a section, the system toggles that section on and will ignore subsequent commands
to turn that section off for the next 5 seconds until the section has entered the un-applied area.
For sections at the end of larger sections or where sharp turns or aggressive maneuvering is necessary, this
override may cause unexpected skips in coverage. The aggressiveness factor uses the user defined look-
ahead values to adjust section control response for these driving styles and/or field areas requiring aggressive
maneuvering when crossing apply zones.
The section control aggressiveness factor adds a percentage of the current turn-on or turn-off look-ahead
setting to the time which the automatic section control feature overrides subsequent zone boundaries.
Summary of Contents for OmniSeed Viper Pro
Page 1: ...Viper Pro Software Version 3 10 OmniSeed Calibration Operation Manual ...
Page 10: ...Table of Contents viii OmniSeed Viper Pro Calibration Operation Manual ...
Page 98: ...Chapter 4 86 OmniSeed Viper Pro Installation Operation Manual ...
Page 150: ...Chapter 6 138 OmniSeed Viper Pro Installation Operation Manual ...
Page 222: ...Chapter 10 210 OmniSeed Viper Pro Installation Operation Manual ...
Page 240: ...Chapter 11 228 OmniSeed Viper Pro Installation Operation Manual ...
Page 251: ...Manual No 016 3001 015 Rev C 239 FIGURE 2 OmniSeed System Diagram 3 Bin D N 054 3001 026 ...
Page 256: ...Appendix A 244 OmniSeed Viper Pro Installation Operation Manual ...
Page 284: ...Appendix D 272 OmniSeed Viper Pro Installation Operation Manual ...
Page 292: ...Appendix G 280 OmniSeed Viper Pro Installation Operation Manual ...
Page 300: ...Appendix H 288 OmniSeed Viper Pro Installation Operation Manual ...
Page 304: ...Index 292 OmniSeed Viper Pro Calibration Operation Manual ...
Page 307: ......