Manual No. 016-3001-015 Rev. C
255
Valve Cal
To ensure that the proper amount of product is being applied, the valve cal must be programmed for the type of
control valve(s) connected to the control system. The field computer uses the valve calibration number to
adjust the response time of the control valve motor to changes in the vehicle speed.
The following control valve calibration numbers are recommended for the valves listed:
Each digit in the calibration number corresponds to a specific function of the valve. The following functions
apply to the digits in the valve calibration number:
Valve Backlash Digit
This value controls the time of the first correction pulse after detecting a change in correction direction. The
values range from 1 to 9, where 1 is for a short pulse and 9 is for a long pulse.
Note:
The backlash digit is not used with a fast, fast close, PWM, PWM close or standard motor control
valve.
Valve Speed Digit
This value controls the response time of the control valve motor. If the valve speed setting is too fast, the valve
will over correct and the system can start to oscillate. The following valves have specific values:
•
Standard Control Valve: This valve has a range of values from 1 to 9, with 1 being slow and 9 being fast.
•
Fast and Fast Close Control Valve: These valves have a range of values from 0 to 9, with 0 for fast and 9 for
slow.
Note:
The speed digit is not used with a PWM or PWM close valve.
Brake Point Digit
The Brake Point digit sets the percent away from the target rate at which the control valve starts to turn at a
slower rate so that it does not overshoot the target rate. The values range from 0 to 9, where 0 is a 5% rate, 1
is a 10% rate and 9 is a 90% rate.
Dead Band Digit
The Dead Band digit is the allowable difference between the target rate and the actual application rate. The
values range from 1 to 9, where 1 equals 1% difference and 9 equals 9% of the difference.
Control Valve Type
Valve Cal
Standard (C-SD)
2123
Fast (C-F) or Fast Close (C-FC)
743
PWM (C-P) or PWM Close (C-PC)
43
Dead Band Digit
Break Point Digit
Valve Backlash Digit
Valve Speed Digit
Summary of Contents for OmniSeed Viper Pro
Page 1: ...Viper Pro Software Version 3 10 OmniSeed Calibration Operation Manual ...
Page 10: ...Table of Contents viii OmniSeed Viper Pro Calibration Operation Manual ...
Page 98: ...Chapter 4 86 OmniSeed Viper Pro Installation Operation Manual ...
Page 150: ...Chapter 6 138 OmniSeed Viper Pro Installation Operation Manual ...
Page 222: ...Chapter 10 210 OmniSeed Viper Pro Installation Operation Manual ...
Page 240: ...Chapter 11 228 OmniSeed Viper Pro Installation Operation Manual ...
Page 251: ...Manual No 016 3001 015 Rev C 239 FIGURE 2 OmniSeed System Diagram 3 Bin D N 054 3001 026 ...
Page 256: ...Appendix A 244 OmniSeed Viper Pro Installation Operation Manual ...
Page 284: ...Appendix D 272 OmniSeed Viper Pro Installation Operation Manual ...
Page 292: ...Appendix G 280 OmniSeed Viper Pro Installation Operation Manual ...
Page 300: ...Appendix H 288 OmniSeed Viper Pro Installation Operation Manual ...
Page 304: ...Index 292 OmniSeed Viper Pro Calibration Operation Manual ...
Page 307: ......